Difference between revisions of "NVR/Recording Setup/Physical Alarm"
(7 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
=Recorder Alarm Setup= | =Recorder Alarm Setup= | ||
− | ==Description== | + | ==Description== |
+ | This article is to show you instruction of how to wire and setup the alarm input from the recorder. | ||
+ | |||
==Prerequisites== | ==Prerequisites== | ||
+ | |||
+ | 1. NVR/HCVR/DVR with Alarm IN relay functionality | ||
+ | |||
+ | 2. Alarm input device. Such as: Toggle switch or motion sensor. | ||
+ | |||
+ | 3. Power supply unit rated for the Electronic Buzzer (and the NVR/HCVR/DVR) | ||
+ | |||
==Video Tutorial== | ==Video Tutorial== | ||
==Step by Step Instructions== | ==Step by Step Instructions== | ||
Line 8: | Line 17: | ||
'''STEP 1.''' Identify the connections on the Alarm Trigger. | '''STEP 1.''' Identify the connections on the Alarm Trigger. | ||
− | [[File:physical_alarm_pic_1.png| | + | |
+ | [[File:physical_alarm_pic_1.png|500px]] | ||
* '''COM''': Communication Port or Ground N.C: Normally Closed - A Trigger that initiates when an object disrupts the communication line of 2 sensors | * '''COM''': Communication Port or Ground N.C: Normally Closed - A Trigger that initiates when an object disrupts the communication line of 2 sensors | ||
Line 19: | Line 29: | ||
*Alarm Inputs are grouped in fours. | *Alarm Inputs are grouped in fours. | ||
*Each group uses the Communication/Ground Port on the right. Alarm Inputs are grouped in fours. Each group uses the Communication/Ground Port on the right. | *Each group uses the Communication/Ground Port on the right. Alarm Inputs are grouped in fours. Each group uses the Communication/Ground Port on the right. | ||
− | |||
+ | [[File:physical_alarm_2.png|500px]] | ||
− | |||
− | |||
+ | '''STEP 3.''' From your local GUI, right click on your live view screen and click on '''Main Menu'''. | ||
+ | [[File:alarm_pic_3.png|300px]] | ||
− | |||
− | |||
+ | '''STEP 4.'''Click '''Event''' from the Settings menu option. | ||
− | + | [[File:physical_alarm_pic_4.png|600px]] | |
− | [[File: | ||
− | '''STEP | + | '''STEP 5.''' From the left menu tab, click '''Alarm'''. |
− | |||
+ | [[File:physical_alarm_pic_5.png|600px]] | ||
− | |||
− | |||
+ | '''STEP 6.''' Click on '''Local Alarm''' tab. | ||
+ | [[File:physical_alarm_pic_6.png|600px]] | ||
− | '''STEP 8.''' Select alarm trigger | + | |
+ | |||
+ | '''STEP 7.''' Select the '''Alarm In''' Port you connected from Step 2. | ||
+ | |||
+ | [[File:physical_alarm_pic_7.png|600px]] | ||
+ | |||
+ | |||
+ | |||
+ | '''STEP 8.''' Select alarm trigger '''Type''' | ||
*'''Normally Closed:''' A Trigger that initiates when an object disrupts the communication line of 2 sensors. | *'''Normally Closed:''' A Trigger that initiates when an object disrupts the communication line of 2 sensors. | ||
*'''Normally Open:''' A Trigger that initiates when an object completes the communication line of 2 sensors. | *'''Normally Open:''' A Trigger that initiates when an object completes the communication line of 2 sensors. | ||
− | |||
+ | [[File:physical_alarm_pic_8.png|600px]] | ||
− | '''STEP 9. Configure the Alarm Trigger Settings | + | |
+ | '''STEP 9.''' Configure the Alarm Trigger Settings | ||
*'''Show Message:''' An alert will appear on the display attached to the system when the alarm is triggered. | *'''Show Message:''' An alert will appear on the display attached to the system when the alarm is triggered. | ||
*'''Record Channel:''' Configure the alarm to trigger recording on a specific channel, or all. | *'''Record Channel:''' Configure the alarm to trigger recording on a specific channel, or all. | ||
*'''Snapshot:''' A Snapshot will be taken by a specific channel or all when the alarm is triggered. | *'''Snapshot:''' A Snapshot will be taken by a specific channel or all when the alarm is triggered. | ||
− | |||
+ | [[File:physical_alarm_9.png|600px]] | ||
− | |||
− | |||
+ | '''STEP 10.''' Click '''Apply'''. | ||
+ | [[File:physical_alarm_pic_10.png|600px]] | ||
− | '''STEP 11.''' Click | + | |
+ | |||
+ | '''STEP 11.''' Click '''OK''' | ||
*If you configured the Alarm to "Show a Message", it will appear as soon as the alarm is triggered. | *If you configured the Alarm to "Show a Message", it will appear as soon as the alarm is triggered. | ||
− | [[File:physical_alarm_pic_11.png| | + | [[File:physical_alarm_pic_11.png|600px]] |
*Right-Click your mouse once to clear the message. | *Right-Click your mouse once to clear the message. | ||
− | [[File:physical_alarm_pic_12.png| | + | [[File:physical_alarm_pic_12.png|600px]] |
+ | |||
[[Category:Alarm]] | [[Category:Alarm]] | ||
[[Category:Record]] | [[Category:Record]] | ||
− | + | [[Category:How To]] | |
− | + | [[Category:Setup]] | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Latest revision as of 19:47, 2 August 2019
Contents
Recorder Alarm Setup
Description
This article is to show you instruction of how to wire and setup the alarm input from the recorder.
Prerequisites
1. NVR/HCVR/DVR with Alarm IN relay functionality
2. Alarm input device. Such as: Toggle switch or motion sensor.
3. Power supply unit rated for the Electronic Buzzer (and the NVR/HCVR/DVR)
Video Tutorial
Step by Step Instructions
Please Note: Setting up alarm triggers will only work with recorders that have alarm inputs.
STEP 1. Identify the connections on the Alarm Trigger.
- COM: Communication Port or Ground N.C: Normally Closed - A Trigger that initiates when an object disrupts the communication line of 2 sensors
- N.C: Normally Closed - A Trigger that initiates when an object disrupts the communication line of 2 sensors
- N.O: Normally Open - A Trigger that initiates when an object completes the communication line of 2 sensors.
STEP 2. Connect the N.C. (Normally Closed) wire to one of the numbered ports. Connect the COM wire to the COM / Ground Port.
- Alarm Inputs are grouped in fours.
- Each group uses the Communication/Ground Port on the right. Alarm Inputs are grouped in fours. Each group uses the Communication/Ground Port on the right.
STEP 3. From your local GUI, right click on your live view screen and click on Main Menu.
STEP 4.Click Event from the Settings menu option.
STEP 5. From the left menu tab, click Alarm.
STEP 6. Click on Local Alarm tab.
STEP 7. Select the Alarm In Port you connected from Step 2.
STEP 8. Select alarm trigger Type
- Normally Closed: A Trigger that initiates when an object disrupts the communication line of 2 sensors.
- Normally Open: A Trigger that initiates when an object completes the communication line of 2 sensors.
STEP 9. Configure the Alarm Trigger Settings
- Show Message: An alert will appear on the display attached to the system when the alarm is triggered.
- Record Channel: Configure the alarm to trigger recording on a specific channel, or all.
- Snapshot: A Snapshot will be taken by a specific channel or all when the alarm is triggered.
STEP 10. Click Apply.
STEP 11. Click OK
- If you configured the Alarm to "Show a Message", it will appear as soon as the alarm is triggered.
- Right-Click your mouse once to clear the message.