Notice: Firmware Links Under Maintenance We are currently undergoing maintenance on all firmware links. If any links are inaccessible, please email or contact Tech Support for the firmware. We appreciate your patience during the maintenance, thank you for your understanding.

Difference between revisions of "Troubleshoot/NVR/Alarm Null"

(Alarm function is null)
 
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
===Alarm function is null===
+
==Alarm function is null==
  
If you are experiencing a nonfunctional or non working alarm then you might want to consider that you have hooked up the alarm incorrectly.
+
If you are experiencing a nonfunctional or non working alarm then you might want to consider that the alarm was setup incorrectly.
  
Here are some resources which could guide you towards getting your alarm system out of a null state.
 
  
To reset your event options take a look at:[[Unable_To_Disarm_Alarm]] and [[How_To_Connect_Electronic_Buzzer]] to find out how the alarm functions are setup on an NVR
+
===Resources for Alarm Systems===
 +
 
 +
* Reset your event options:[[Troubleshoot/NVR/Unable_To_Disarm_Alarm| Unable to Disarm Alarm]]  
 +
* How the alarm functions are setup on an NVR[[Access_Control/How_To_Connect_Electronic_Buzzer|How to Connect Electronic Buzzer]]
 +
 
 +
===Possible Problems:===
  
 
Here are also some possible problems that may have occurred upon setup:
 
Here are also some possible problems that may have occurred upon setup:
 +
 
* Alarm is not setup correctly (event settings can be incorrect)
 
* Alarm is not setup correctly (event settings can be incorrect)
 +
[[File:ElectBuzzer012.jpg|500x500px]]
 +
 +
 
* Alarm cable connection is not correct (check your connections)
 
* Alarm cable connection is not correct (check your connections)
* Alarm input signal is not correct, the alarm inputs need low voltage (< 2.0 VDC)
+
[[File:ElectBuzzer010.jpg|500x500px]]
* There are two loops connect to one alarm device (check your wiring)
+
 
* The protection zone the intruder entering has not enabled the arm function or the intruder has enough knowledge to disable the system.  
+
[[File:ElectBuzzer009.jpg|500x500px]]
* The siren device installation position is not right and it does not have the warning function.  
+
 
* The detector is null when there is an alarm outage (check other alarm inputs)
+
 
* The detector is not in the proper position and can not detect the corresponding zone (reset the angle of the sensor)  
+
* The alarm input signal might not be correct, the alarm input supplies a low voltage (< 2.0 VDC). If you are supplying a voltage in excess of that to show a closed or open signal then you will need to wire a resistor into the circuit to get the proper voltage to the alarm input pin out.
* System can not generate an alarm when there is something wrong with the alarm signal transmission system (the service is disabled, there is malicious attack and etc)
+
 
* The device is null resulting from non-schedule maintenance of the alarm system (has someone worked on the system recently?)  
+
* There are two loops connect to one alarm device, which will send a false signal or keep the circuit open (check your wiring).
 +
 
 +
* The protection zone that the intruder is entering has not been enabled (in the IVS rules setup, and IVS event) the arm function or the intruder has enough knowledge to disable the system. See [[IVS/Intrusion_Detect|Intrusion Detect]] for more details.
 +
 
 +
* The siren output device is incorrect on the back of the recorder and does have the warning function setup correctly. Make sure the siren wired into NO1 and C1 correspond with  alarm out 1 when configuring your setup.
 +
[[File:ElectBuzzer011.jpg|500x500px]]
 +
 
 +
* If the detector (alarm input) is not working when there is an alarm outage, you might have wired your alarm input into your alarm output or input. (check your wiring)
 +
 
 +
* The detector (i.e. door sensor, PIR sensor) might not be in the proper position and can not detect the corresponding zone (reset the angle of the sensor)
 +
 
 +
* The recording system can not generate an alarm when there is something wrong with the alarm signal transmission system (the service is disabled, there is malicious attack and etc)
 +
 
 +
* The device is not working, resulting from non-schedule maintenance of the alarm system (has someone worked on the system recently?)
  
Sometimes it is best to call the engineer who setup your alarm system if you do not know what you are doing, as tampering with some systems can set of subsequent systems.
+
== Please Be Advised ==
 +
Sometimes it is best to call the engineer who setup your alarm system if you do not know what you are doing, as tampering with some systems can set off subsequent systems.
  
  

Latest revision as of 17:58, 17 August 2016

Alarm function is null

If you are experiencing a nonfunctional or non working alarm then you might want to consider that the alarm was setup incorrectly.


Resources for Alarm Systems

Possible Problems:

Here are also some possible problems that may have occurred upon setup:

  • Alarm is not setup correctly (event settings can be incorrect)

ElectBuzzer012.jpg


  • Alarm cable connection is not correct (check your connections)

ElectBuzzer010.jpg

ElectBuzzer009.jpg


  • The alarm input signal might not be correct, the alarm input supplies a low voltage (< 2.0 VDC). If you are supplying a voltage in excess of that to show a closed or open signal then you will need to wire a resistor into the circuit to get the proper voltage to the alarm input pin out.
  • There are two loops connect to one alarm device, which will send a false signal or keep the circuit open (check your wiring).
  • The protection zone that the intruder is entering has not been enabled (in the IVS rules setup, and IVS event) the arm function or the intruder has enough knowledge to disable the system. See Intrusion Detect for more details.
  • The siren output device is incorrect on the back of the recorder and does have the warning function setup correctly. Make sure the siren wired into NO1 and C1 correspond with alarm out 1 when configuring your setup.

ElectBuzzer011.jpg

  • If the detector (alarm input) is not working when there is an alarm outage, you might have wired your alarm input into your alarm output or input. (check your wiring)
  • The detector (i.e. door sensor, PIR sensor) might not be in the proper position and can not detect the corresponding zone (reset the angle of the sensor)
  • The recording system can not generate an alarm when there is something wrong with the alarm signal transmission system (the service is disabled, there is malicious attack and etc)
  • The device is not working, resulting from non-schedule maintenance of the alarm system (has someone worked on the system recently?)

Please Be Advised