Difference between revisions of "EventAlarm"

(Flash Set)
(Audio Detect)
Line 186: Line 186:
  
 
==Audio Detect==
 
==Audio Detect==
 +
Note: Audio detection won’t work when “Talk” is enabled on the preview interface.
 +
 +
[[file:IPCEventAudioDetect1.jpg|800px]]
 +
 +
{| class="wikitable" width="643"
 +
|-
 +
| width="106"|
 +
'''parameter'''
 +
 +
| width="536"|
 +
'''Function '''
 +
 +
|-
 +
| width="106"|
 +
Enable
 +
 +
| width="536"|
 +
Check it and enable audio detection.
 +
 +
|-
 +
| width="106"|
 +
Threshold
 +
 +
| width="536"|
 +
It will trigger alarm and set up a series of linkage when volume exceeds the set threshold.
 +
 +
|}

Revision as of 19:52, 14 October 2015

Event Alarm

PIR Alarm

IPCEventPIRAlarm.jpg

Parameter

Function

Enable

After enabled, relay activation will work. Check it and enable the PIR alarm.

Working period

  • This function becomes activated in the specified periods.
  • There are six periods in one day. Please draw a circle to enable corresponding period.
  • Select date. If you do not select, current setup applies to today only. You can select all week column to apply to the whole week.
  • Click OK button, system goes back to motion detection interface; please click save button to exit.

Note: User can set via dragging mouse while not releasing left mouse.

Anti-dither

System only memorizes one event during the anti-dither period. The value ranges from 0s to 100s.

Flash

After enabling, the system will automatically turn on the flash when alarm occurs.

Flash Delay

  • The flash will be off with a period of time delay when the alarm linkage is over.
  • Time is calculated by unit of second and ranges from 10s~300s.

Record

System auto activates motion detection channel to record once alarm occurs (working with motion detection function).

Record Delay

System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s.

Relay out

Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs. 

Alarm delay

System can delay the alarm output for specified time after alarm ended. The value ranges from 10s to 300s.

Send Email

After this function is enabled, system can send out email to alert you when alarm occurs and ends.

Audio Linkage

Check it and the system will play alarm audio file when alarm occurs. Users can set recorded audio file in “Camera Setting >Audio >Alarm Audio”.

Snapshot

After you enabled snapshot, the system will automatically snapshot if alarm occurs.

Relay Activation

IPCEventRelayActivation.jpg

Parameter

Function

Enable

Check it and enable the alarm linkage.

Relay-in

The default alarm 1,some products can choose alarm 2.

Sensor Type

Two types of sensor which are normally open (NO) and normally closed (NC), switch from normally open to normally closed, open the alarm. Switch from normally closed to normally open, shut the alarm.

PTZ

Check it and set PTZ movement when alarm occurs. Such as go to preset x when there is an alarm.

The event type includes: preset, tour and pattern and so on.

Flash Set

IPCEventFlashSet.jpg

Parameter

Function

ON/OFF

ON means flash is on; OFF means flash is off.

Weak-strong bar

Via dragging this bar to adjust flash brightness.

All

Check and it means the day flash works.

Period

Period that flash is on.

Audio Detect

Note: Audio detection won’t work when “Talk” is enabled on the preview interface.

IPCEventAudioDetect1.jpg

parameter

Function

Enable

Check it and enable audio detection.

Threshold

It will trigger alarm and set up a series of linkage when volume exceeds the set threshold.