Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Contact 2) |
|||
Line 94: | Line 94: | ||
|ALARM2 | |ALARM2 | ||
|Alarm 2 input port. | |Alarm 2 input port. | ||
+ | |} | ||
+ | ===Contact 3=== | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON3 | ||
+ | |- | ||
+ | |rowspan="9"|CON3 | ||
+ | |- | ||
+ | |Black and red | ||
+ | |RX | ||
+ | |RS-232 receiving port. | ||
+ | |- | ||
+ | |Black and orange | ||
+ | |TX | ||
+ | |RS-232 sending port. | ||
+ | |- | ||
+ | |Black and blue | ||
+ | |GND | ||
+ | |Connected to the common GND port. | ||
+ | |- | ||
+ | |Black and gray | ||
+ | |SR1 | ||
+ | |Used for door contact detection. | ||
+ | |- | ||
+ | |Black and green | ||
+ | |PUSH1 | ||
+ | |Door open button of door No.1 | ||
+ | |- | ||
+ | |Black and brown | ||
+ | |DOOR1_COM | ||
+ | |Lock control common port. | ||
+ | |- | ||
+ | |Black and yellow | ||
+ | |DOOR1_NO | ||
+ | |Lock control normally open port. | ||
+ | |- | ||
+ | |Black and purple | ||
+ | |DOOR1_NC | ||
+ | |Lock control normally closed port. | ||
|} | |} |
Revision as of 17:20, 18 June 2020
Contents
Alarm Input and Output
Cable Connections
- Alarm1 = Normal
- Alarm2 = High Temp
- No alert for mask or face detection currently.
Contact 1
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON1 | |||
Black | RD– | Negative electrode of external card reader. | |
Red | RD+ | Positive electrode of external card reader. | |
Blue | CASE | Tamper alarm input of the external card reader. | |
White | D1 | Wiegand D1 input (connected to external card reader)/output (connected to controller). | |
Green | D0 | Wiegand D0 input (connected to external card reader)/output (connected to controller). | |
Brown | LED | Connected to external reader indicator in | |
Yellow | B | RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| |
Purple | A | RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
|
Contact 2
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON2 | |||
White and red | ALARM1_NO | Alarm 1 normally open output port | |
White and orange | ALARM1_COM | Alarm 1 common output port. | |
White and blue | ALARM2_NO | Alarm 2 normally open output port. | |
White and gray | ALARM2_COM | Alarm 2 common output port. | |
White and green | GND | Connected to the common GND port. | |
White Brown | ALARM1 | Alarm 1 input port. | |
White and yellow | GND | Connected to the common GND port. | |
White and purple | ALARM2 | Alarm 2 input port. |
Contact 3
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON3 | |||
Black and red | RX | RS-232 receiving port. | |
Black and orange | TX | RS-232 sending port. | |
Black and blue | GND | Connected to the common GND port. | |
Black and gray | SR1 | Used for door contact detection. | |
Black and green | PUSH1 | Door open button of door No.1 | |
Black and brown | DOOR1_COM | Lock control common port. | |
Black and yellow | DOOR1_NO | Lock control normally open port. | |
Black and purple | DOOR1_NC | Lock control normally closed port. |