Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

(Contact 2)
(Contact 3)
Line 119: Line 119:
 
{| class="wikitable"
 
{| class="wikitable"
 
!|Port
 
!|Port
!|Cable Color
+
!colspan="2"|Cable Color
 
!|Cable Name
 
!|Cable Name
 
!|Description
 
!|Description
Line 128: Line 128:
 
|-
 
|-
 
|Black and red
 
|Black and red
 +
|
 
|RX
 
|RX
 
|RS-232 receiving port.
 
|RS-232 receiving port.
 
|-
 
|-
 
|Black and orange
 
|Black and orange
 +
|
 
|TX
 
|TX
 
|RS-232 sending port.
 
|RS-232 sending port.
 
|-
 
|-
 
|Black and blue
 
|Black and blue
 +
|
 
|GND
 
|GND
 
|Connected to the common GND port.
 
|Connected to the common GND port.
 
|-
 
|-
 
|Black and gray
 
|Black and gray
 +
|
 
|SR1
 
|SR1
 
|Used for door contact detection.
 
|Used for door contact detection.
 
|-
 
|-
 
|Black and green
 
|Black and green
 +
|
 
|PUSH1
 
|PUSH1
 
|Door open button of door No.1
 
|Door open button of door No.1
 
|-
 
|-
 
|Black and brown
 
|Black and brown
 +
|
 
|DOOR1_COM
 
|DOOR1_COM
 
|Lock control common port.
 
|Lock control common port.
 
|-
 
|-
 
|Black and yellow
 
|Black and yellow
 +
|
 
|DOOR1_NO
 
|DOOR1_NO
 
|Lock control normally open port.
 
|Lock control normally open port.
 
|-
 
|-
 
|Black and purple
 
|Black and purple
 +
|
 
|DOOR1_NC  
 
|DOOR1_NC  
 
|Lock control normally closed port.
 
|Lock control normally closed port.
 
|}
 
|}

Revision as of 17:55, 18 June 2020

Alarm Input and Output

Cable Connections
Physical Setup

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black Wire black.svg RD– Negative electrode of external card reader.
Red Wire red.svg RD+ Positive electrode of external card reader.
Blue Wire blue.svg CASE Tamper alarm input of the external card reader.
White Wire white.svg D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green Wire green.svg D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown Wire brown.svg LED Connected to external reader indicator in
Yellow Wire yellow.svg B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red Wire white red stripe.svg ALARM1_NO Alarm 1 normally open output port
White and orange Wire white orange stripe.svg ALARM1_COM Alarm 1 common output port.
White and blue Wire white blue stripe.svg ALARM2_NO Alarm 2 normally open output port.
White and gray Wire white gray stripe.svg ALARM2_COM Alarm 2 common output port.
White and green Wire white green stripe.svg GND Connected to the common GND port.
White Brown Wire white brown stripe.svg ALARM1 Alarm 1 input port.
White and yellow Wire white yellow stripe.svg GND Connected to the common GND port.
White and purple ALARM2 Alarm 2 input port.

Contact 3

Port Cable Color Cable Name Description
CON3
CON3
Black and red RX RS-232 receiving port.
Black and orange TX RS-232 sending port.
Black and blue GND Connected to the common GND port.
Black and gray SR1 Used for door contact detection.
Black and green PUSH1 Door open button of door No.1
Black and brown DOOR1_COM Lock control common port.
Black and yellow DOOR1_NO Lock control normally open port.
Black and purple DOOR1_NC Lock control normally closed port.