RS485

Description

RS485 is a communication port which is based on coaxial cable. It can control the camera via back-end device when the information of RS485 is set in accordance with that of the back-end coding device.

Prerequisites

Instructions

Common RS485 Settings

Device Channel PTZ Type: Protocol Address Baud Rate Data Bit Stop Bit Parity
Dahua SD59230IN-HC 1 Local Pelco-D 1 9600 8 1 None
Hikvision Analog PTZ 1 Local Pelco-D 1 2400 8 1 None

New Template

1. Connect the RS485 cable of the PTZ camera to the RS485 port on the Device. Ensure the match of A and B interfaces.

2. Connect the video out cable of the PTZ camera to the video input port on the Device.

3. Turn on the PTZ camera.

Determine PTZ's Address, Baud, & Protocol

Method 1: Reboot and View OSD

1. Connect Analog or HD-CVI PTZ to Channel 1.

2. Bring up Channel 1 Live View

3. Power cycle PTZ.

4. Wait for PTZ to boot, and watch Channel 1 for PTZ Info.

Method 2: Check Manufacturer's Manual or Specifications

Configure Dahua Recorder

Icon for type SystemUI Old.pngSystemUI Old

Icon for type SystemUI New.pngSystemUI New

Icon for type WebUI Old.pngWebUI Old

Icon for type WebUI New.pngWebUI New