Port
|
Cable Color
|
Cable Name
|
Description
|
CON1
CON1
|
Black
|
|
RD–
|
Negative electrode of external card reader.
|
Red
|
|
RD+
|
Positive electrode of external card reader.
|
Blue
|
|
CASE
|
Tamper alarm input of the external card reader.
|
White
|
|
D1
|
Wiegand D1 input (connected to external card reader)/output (connected to controller).
|
Green
|
|
D0
|
Wiegand D0 input (connected to external card reader)/output (connected to controller).
|
Brown
|
|
LED
|
Connected to external reader indicator in
|
Yellow
|
|
B
|
RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
- If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
- Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
|
Purple
|
|
A
|
RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
- If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
- Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid
|