EventAlarm
Event Alarm
PIR Alarm
Parameter |
Function |
Enable |
After enabled, relay activation will work. Check it and enable the PIR alarm. |
Working period |
Note: User can set via dragging mouse while not releasing left mouse. |
Anti-dither |
System only memorizes one event during the anti-dither period. The value ranges from 0s to 100s. |
Flash |
After enabling, the system will automatically turn on the flash when alarm occurs. |
Flash Delay |
|
Record |
System auto activates motion detection channel to record once alarm occurs (working with motion detection function). |
Record Delay |
System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s. |
Relay out |
Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs. |
Alarm delay |
System can delay the alarm output for specified time after alarm ended. The value ranges from 10s to 300s. |
Send Email |
After this function is enabled, system can send out email to alert you when alarm occurs and ends. |
Audio Linkage |
Check it and the system will play alarm audio file when alarm occurs. Users can set recorded audio file in “Camera Setting >Audio >Alarm Audio”. |
Snapshot |
After you enabled snapshot, the system will automatically snapshot if alarm occurs. |