Thermal/Temperature Monitoring/Camera Configuration

Revision as of 18:52, 24 April 2020 by Marques.Phillips (talk | contribs)

Temperature Monitoring Solution Camera Configuration

This guide will cover the camera Configuration for the Thermal Temperature Monitoring Solution

TPC Configuration Flow.png

Video Instructions

Step by Step Instructions

The camera should be upgraded to the correct firmware and initialized before setup. Please follow How To Update TPC-BF5421-T Firmware before attempting this guide

Check latest firmware and upgrade

Open smart thermal of human body temperature measurement

TEST

Set rules of human temperature measurement

TEST

Set blackbody parameters

TEST

Set intelligent detect channel

TEST

Check environment temperature

Check Environment Temperature

If the default temperature parameters are not accurate this situation will affect the human body temperature measurement.

If human body temperature is inaccurate, try the following steps:

Step 1 - Ambient temperature

  • Log into Camera
    • Setting > Smart Thermal > Human temperature measurement > Others

Temperature Monitoring - Camera Configuration - 19.jpg

  • Use thermometer to detect the real ambient temperature on site and enter the number

Temperature Monitoring - Camera Configuration - 21.jpg

Temperature Monitoring - Camera Configuration - 22.jpg

  • Click Save

Step 2 - Human temperature correction

  • Use a thermometer to detect the real Human body temperature:

Thermometer.JPG

Calculate the difference between real Human body temperature and measure the temperature from the thermal camera, enter this value in Human Temperature correction field.

Smart Thermal > Human Temperature Monitoring > Blackbody parameter:

Temperature Monitoring - Camera Configuration - 24.jpg

For example: real Human body temperature is 98.6F (37C), measure temperature in thermal camera is 100F (37.8C)

Human Temperature correction should be 98.6 - 100 = -1.4

Click Save

Effect Verification

TEST