Thermal/Temperature Monitoring

Revision as of 22:05, 7 December 2022 by Nicky Gunakan (talk | contribs) (Solution Features)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Temperature Monitoring

Description

The Dahua Thermal Temperature Monitoring Solution offers the latest hybrid thermal network camera that combines a Vanadium Oxide (VOx) sensor with a 2 MP visible-light sensor. The solution also provides a blackbody calibration device that maintains a constant temperature as a reference point for the thermal camera. The thermal camera coupled with the blackbody calibration device and a feature-rich 4 TB Network Video Recorder delivers a contactless solution for continuous, contactless, and non-invasive temperature monitoring.

'The Dahua Thermal Temperature Monitoring Solution is not FDA-cleared or approved. The Solution should not be solely or primarily used to diagnose or exclude a diagnosis of COVID-19 or any other disease. Elevated skin temperature in the context of use should be confirmed with secondary evaluation methods (e.g., an NCIT or clinical grade contact thermometer). Public health officials, through their experience with the Solution in the particular environment of use, should determine the significance of any fever or elevated temperature based on the skin telethermographic temperature measurement. The Solution should be used to measure only one subject’s temperature at a time. Visible thermal patterns are only intended for locating the points from which to extract the thermal measurement.

Instructions

Physical Setup
Camera Standalone
NVR Initial Setup
Camera Standalone
Standalone Camera Setup Camera + NVR Setup
Camera Standalone Camera + NVR
Setup for camera connected to LAN Setup for camera connected to NVR
Add to NVR Add to NVR
Camera Standalone Camera + NVR
Add Thermal Camera to NVR and setup recording Add Thermal Camera to NVR and setup recording
Camera Configuration
Camera Standalone

Video Example

Full Setup Video:

Required Devices

Recommended Accesories

  • VCT-999 Tripod (x2)
  • RQW026-00 Connector (x2)

A set of temperature equipment requires two tripods and two transfer parts, one for the camera and one for the Blackbody device

Required Firmware

The camera will require installing 2 different firmware files, one for the System and one for the Core.

The upgrade for the camera will require a single set of System and Core files. Download both System and Core files as a pair, do not interchange/mix the files between the sets listed below.

The System firmware should be installed first then the Core firmware

The firmware files below are specific for the Temperature Monitoring Solution. For general use please reference the firmware listed on Firmware By Device

To determine what firmware to use on Model:DH-TPC-BF5421-T, locate the P/N on the box of the unit and compare to the chart below


Camera Model System Firmware Core Firmware
DH-TPC-BF3221-T

Build Date: 8-15-2020

Build Date: 4-24-2020
DH-TPC-BF5421-T For P/N : 1.0.01.34.11801 and 1.0.01.34.11823
Set 1 - D

Build Date: 10-15-2020
Set 1 - D

Build Date: 7-3-2020
For P/N : 1.0.01.34.11756
Set 2 - B

Build Date: 7-16-2020
Set 2 - B

Build Date: 4-24-2020
NVR Model Firmware
DHI-NVR5216-16P-I

Build Date: 07-30-2021

Solution Diagrams


Distance between camera and blackbody Distance between the human forehead and the camera Channel Width
9.8 ft (3m) 9.8 ft (3m) 4.3 ft (1.3m)

3rd Party VMS Integration

Specifications