Difference between revisions of "Thermal/Calibrate Blackbody"

(Created page with "=How to Configure the Blackbody= ==Description== This article will go over how to configure the Blackbody. ==Prerequistes== * DH-TPC-BF3221-T or DH-TPC-BF5421-T Thermal Hy...")
 
 
(9 intermediate revisions by 2 users not shown)
Line 4: Line 4:
 
This article will go over how to configure the Blackbody.  
 
This article will go over how to configure the Blackbody.  
  
==Prerequistes==
+
==Prerequisites==
  
 
* DH-TPC-BF3221-T or DH-TPC-BF5421-T Thermal Hybrid Network Camera
 
* DH-TPC-BF3221-T or DH-TPC-BF5421-T Thermal Hybrid Network Camera
Line 10: Line 10:
  
 
==Video Instructions==
 
==Video Instructions==
<embedvideo service="youtube">https://youtu.be/es9kmGNBykQ</embedvideo>
+
<embedvideo service="youtube">https://youtu.be/nUf_qbFc484</embedvideo>
 +
 
 +
==Step by Step Instructions==
 +
 
 +
1. Login to the Thermal Camera
 +
 
 +
[[File:Configure Blackbody-1.png|800px]]
 +
 
 +
2. Go to Smart Thermal> Smart Plan> and enable Thermal Temperature Monitor. Save
 +
 
 +
[[File:Configure Blackbody-2.png|800px]]
 +
 
 +
3. On the left menu tab go to Thermal Temperature>Blackbody Parameter and enable.
 +
 
 +
- Leave the black box permanently at 35°C (95°F) <br />
 +
- Draw the area around the inner plate of the Blackbody box for accurate readings
 +
 
 +
[[File:Thermal Monitoring Setup-4.png|800px]]
 +
 
 +
Make sure the Blackbody box is set to 35°C (95°F) to reflect the settings in the camera
 +
 
 +
[[File:Configure Blackbody-4.JPG|800px]]

Latest revision as of 18:59, 8 June 2020

How to Configure the Blackbody

Description

This article will go over how to configure the Blackbody.

Prerequisites

  • DH-TPC-BF3221-T or DH-TPC-BF5421-T Thermal Hybrid Network Camera
  • JQ-D70Z Blackbody

Video Instructions

Step by Step Instructions

1. Login to the Thermal Camera

Configure Blackbody-1.png

2. Go to Smart Thermal> Smart Plan> and enable Thermal Temperature Monitor. Save

Configure Blackbody-2.png

3. On the left menu tab go to Thermal Temperature>Blackbody Parameter and enable.

- Leave the black box permanently at 35°C (95°F)
- Draw the area around the inner plate of the Blackbody box for accurate readings

Thermal Monitoring Setup-4.png

Make sure the Blackbody box is set to 35°C (95°F) to reflect the settings in the camera

Configure Blackbody-4.JPG