Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Normal Body Temperature Indication Light) |
|||
(47 intermediate revisions by 3 users not shown) | |||
Line 2: | Line 2: | ||
[[file:DHI-ASI7213X-T1_Cable_Connections.png|thumb|Cable Connections]] | [[file:DHI-ASI7213X-T1_Cable_Connections.png|thumb|Cable Connections]] | ||
[[file:DHI-ASI7213X-T1_Physical_Setup.png|thumb|Physical Setup]] | [[file:DHI-ASI7213X-T1_Physical_Setup.png|thumb|Physical Setup]] | ||
+ | |||
+ | |||
+ | {| class="wikitable" | ||
+ | ! style="text-align:center;"|[https://dahuawiki.com/index.php?action=ajax&title=-&rs=SecureFileStore::getFile&f=/c/c7/DHI-ASI7213X-T1_Contacts_Print_Sheet.xlsx <ul class="fa-ul"><li><i class="fas fa-file-pdf fa-4x" style="color:darkred;></i></li></ul>]DHI-ASI7213X-T1 Contacts Reference Sheet | ||
+ | |} | ||
+ | |||
==Web Interface== | ==Web Interface== | ||
<gallery> | <gallery> | ||
Line 10: | Line 16: | ||
==Cable Connections== | ==Cable Connections== | ||
− | *Alarm1 = | + | *Alarm1 = High Temp |
− | *Alarm2 = | + | *Alarm2 = Normal Temp or No Mask |
− | *No alert for | + | *No alert for face detection currently. |
===Contact 1=== | ===Contact 1=== | ||
Line 132: | Line 138: | ||
|- | |- | ||
|rowspan="9"|CON3 | |rowspan="9"|CON3 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|Black and blue | |Black and blue | ||
Line 173: | Line 169: | ||
|Lock control normally closed port. | |Lock control normally closed port. | ||
|} | |} | ||
− | == | + | |
+ | ==Alarm Outputs 1 and 2 - New Firmware== | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | !|PLEASE NOTE: These instructions are for Alarm Outputs 1 and 2 on firmware version 1.000.10BE001.0.R.200722 and later | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ===High Body Temperature Indication Light=== | ||
+ | [[File:High Temp Alarm Setup-newfw.png|700px|right]] | ||
{| class="wikitable" | {| class="wikitable" | ||
!|Port | !|Port | ||
Line 193: | Line 199: | ||
|ALARM1_COM | |ALARM1_COM | ||
|Alarm 1 common output port. | |Alarm 1 common output port. | ||
+ | |- | ||
+ | |} | ||
+ | <br><br><br><br><br><br><br><br><br><br><br><br><br><br> | ||
+ | |||
+ | ===Normal Body Temperature or No Mask Indication Light=== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | !|PLEASE NOTE: On firmware version 1.000.10BE001.0.R.200722 and later, you must set the Alarm Output 2 mode setting to either "Normal Temperature Alarm" for being triggered when a normal temperature is detected or "No Mask Alarm" for being triggered when no mask is detected | ||
+ | |- | ||
+ | |[[File:ThermalKioskAlarmOutput2.PNG|600px|center]] | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | [[File:Normal Temp alarm Setup-newfw.png|700px|right]] | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON2 | ||
+ | |- | ||
+ | |rowspan="9"|CON2 | ||
|- | |- | ||
|White and blue | |White and blue | ||
Line 203: | Line 232: | ||
|ALARM2_COM | |ALARM2_COM | ||
|Alarm 2 common output port. | |Alarm 2 common output port. | ||
+ | |} | ||
+ | <br><br><br><br><br><br><br><br><br><br><br><br><br><br> | ||
+ | |||
+ | ==Alarm Outputs 1 and 2 - Old Firmware== | ||
+ | {| class="wikitable" | ||
|- | |- | ||
− | |White and | + | !|PLEASE NOTE: These instructions are for Alarm Outputs 1 and 2 on firmware older than version 1.000.10BE001.0.R.200722 |
− | |[[File: | + | |- |
+ | |} | ||
+ | |||
+ | ===High Body Temperature Indication Light=== | ||
+ | [[File:High Temp Alarm Setup.png |700px|right]] | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON2 | ||
+ | |- | ||
+ | |rowspan="9"|CON2 | ||
+ | |- | ||
+ | |White and blue | ||
+ | |[[File:Wire_white_blue_stripe.svg|35px]] | ||
+ | |ALARM2_NO | ||
+ | |Alarm 2 normally open output port. | ||
+ | |- | ||
+ | |White and gray | ||
+ | |[[File:Wire_white_gray_stripe.svg|35px]] | ||
+ | |ALARM2_COM | ||
+ | |Alarm 2 common output port. | ||
+ | |} | ||
+ | <embedvideo service="youtube">https://youtu.be/5gC_ptUkYD8</embedvideo> | ||
+ | |||
+ | ===Normal Body Temperature Indication Light=== | ||
+ | [[File:Normal Temp alarm Setup.png|700px|right]] | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON2 | ||
+ | |- | ||
+ | |rowspan="9"|CON2 | ||
+ | |- | ||
+ | |White and red | ||
+ | |[[File:Wire_white_red_stripe.svg|35px]] | ||
+ | |ALARM1_NO | ||
+ | |Alarm 1 normally open output port | ||
+ | |- | ||
+ | |White and orange | ||
+ | |[[File:Wire_white_orange_stripe.svg|35px]] | ||
+ | |ALARM1_COM | ||
+ | |Alarm 1 common output port. | ||
+ | |- | ||
+ | |} | ||
+ | <embedvideo service="youtube">https://youtu.be/5toY3dhp2fI</embedvideo> | ||
+ | |||
+ | ==Door Strike Physical Setup== | ||
+ | [[File:Door Strike Physical Setup.png|700px|right]] | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON3 | ||
+ | |- | ||
+ | |rowspan="9"|CON3 | ||
+ | |- | ||
+ | |Black and brown | ||
+ | |[[File:Wire_black_brown_stripe.svg|35px]] | ||
+ | |DOOR1_COM | ||
+ | |Lock control common port. | ||
+ | |- | ||
+ | |Black and purple | ||
+ | |[[File:Wire_black_purple_stripe.png|35px]] | ||
+ | |DOOR1_NC | ||
+ | |Lock control normally closed port. | ||
+ | |} | ||
+ | <embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | ||
+ | |||
+ | ==Door Release Button Physical Setup== | ||
+ | |||
+ | [[File:Door Release Button Physical Setup.png|700px|right]] | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON3 | ||
+ | |- | ||
+ | |rowspan="9"|CON3 | ||
+ | |- | ||
+ | |Black and blue | ||
+ | |[[File:Wire_black_blue_stripe.svg|35px]] | ||
|GND | |GND | ||
|Connected to the common GND port. | |Connected to the common GND port. | ||
|- | |- | ||
− | |White | + | |Black and green |
− | |[[File: | + | |[[File:Wire_black_green_stripe.svg|35px]] |
− | | | + | |PUSH1 |
− | | | + | |Door open button of door No.1 |
+ | |- | ||
+ | |} | ||
+ | <embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | ||
+ | |||
+ | ==Card Reader:RS485== | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON1 | ||
+ | |- | ||
+ | |rowspan="9"|CON1 | ||
+ | |- | ||
+ | |Yellow | ||
+ | |[[File:Wire_yellow.svg|35px]] | ||
+ | |B | ||
+ | |RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
+ | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
+ | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid. | ||
+ | |- | ||
+ | |Purple | ||
+ | |[[File:Wire_purple.png|35px]] | ||
+ | |A | ||
+ | |RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
+ | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
+ | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid | ||
+ | |} | ||
+ | <gallery> | ||
+ | file:DHI-ASI7213X-T1_Door_Config_DSS-Express.png|Door Config in DSS Express | ||
+ | </gallery> | ||
+ | |||
+ | ==Card Reader:Wiegand== | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON1 | ||
+ | |- | ||
+ | |rowspan="9"|CON1 | ||
+ | |- | ||
+ | |White | ||
+ | |[[File:Wire_white.svg|35px]] | ||
+ | |D1 | ||
+ | |Wiegand D1 input (connected to external card reader)/output (connected to controller). | ||
|- | |- | ||
− | | | + | |Green |
− | |[[File: | + | |[[File:Wire_green.svg|35px]] |
− | | | + | |D0 |
− | | | + | |Wiegand D0 input (connected to external card reader)/output (connected to controller). |
|- | |- | ||
− | |||
− | |||
− | |||
− | |||
|} | |} | ||
− | == | + | ==WebUI Alarm Setup== |
+ | <embedvideo service="youtube">https://youtu.be/vjfoiNMyOB8</embedvideo> | ||
+ | ==SystemUI Set Temperature Threshold== | ||
+ | <embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> | ||
− | == | + | ==Notes== |
+ | *Access Link Enable is only used when a door is configured for access for normal temperature. If the Kiosk is only used for LED lights, this option shouldn't be enabled. |
Latest revision as of 15:44, 9 July 2021
Contents
- 1 Alarm Input and Output
- 1.1 Web Interface
- 1.2 Cable Connections
- 1.3 Alarm Outputs 1 and 2 - New Firmware
- 1.4 Alarm Outputs 1 and 2 - Old Firmware
- 1.5 Door Strike Physical Setup
- 1.6 Door Release Button Physical Setup
- 1.7 Card Reader:RS485
- 1.8 Card Reader:Wiegand
- 1.9 WebUI Alarm Setup
- 1.10 SystemUI Set Temperature Threshold
- 1.11 Notes
Alarm Input and Output
Web Interface
Cable Connections
- Alarm1 = High Temp
- Alarm2 = Normal Temp or No Mask
- No alert for face detection currently.
Contact 1
Contact 2
Contact 3
Alarm Outputs 1 and 2 - New Firmware
PLEASE NOTE: These instructions are for Alarm Outputs 1 and 2 on firmware version 1.000.10BE001.0.R.200722 and later |
---|
High Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and red | ALARM1_NO | Alarm 1 normally open output port | ||
White and orange | ALARM1_COM | Alarm 1 common output port. |
Normal Body Temperature or No Mask Indication Light
PLEASE NOTE: On firmware version 1.000.10BE001.0.R.200722 and later, you must set the Alarm Output 2 mode setting to either "Normal Temperature Alarm" for being triggered when a normal temperature is detected or "No Mask Alarm" for being triggered when no mask is detected |
---|
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and blue | ALARM2_NO | Alarm 2 normally open output port. | ||
White and gray | ALARM2_COM | Alarm 2 common output port. |
Alarm Outputs 1 and 2 - Old Firmware
PLEASE NOTE: These instructions are for Alarm Outputs 1 and 2 on firmware older than version 1.000.10BE001.0.R.200722 |
---|
High Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and blue | ALARM2_NO | Alarm 2 normally open output port. | ||
White and gray | ALARM2_COM | Alarm 2 common output port. |
Normal Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and red | ALARM1_NO | Alarm 1 normally open output port | ||
White and orange | ALARM1_COM | Alarm 1 common output port. |
Door Strike Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and brown | DOOR1_COM | Lock control common port. | ||
Black and purple | DOOR1_NC | Lock control normally closed port. |
Door Release Button Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and blue | GND | Connected to the common GND port. | ||
Black and green | PUSH1 | Door open button of door No.1 |
Card Reader:RS485
Card Reader:Wiegand
WebUI Alarm Setup
SystemUI Set Temperature Threshold
Notes
- Access Link Enable is only used when a door is configured for access for normal temperature. If the Kiosk is only used for LED lights, this option shouldn't be enabled.