IP rating consists of 2 numbers, which is a standard for ingress protection. Dahua products are usually IP67.
IP rating consists of 2 numbers, which is a standard for ingress protection. Dahua products are usually IP67.
 
  
 
[[file:IPrating.png]]
 
[[file:IPrating.png]]
  
 
NEMA rating is the same as IP except their numbers goes from 1 to 13 with R,S,X,K as variations.
 
NEMA rating is the same as IP except their numbers goes from 1 to 13 with R,S,X,K as variations.
 +
 +
 +
{| class="tblHead" border="0" width="100%" cellspacing="1" cellpadding="4"
 +
|- class="tbltitle"
 +
| align="center" width="52"|'''NEMA <br />Ratings'''
 +
| align="center" width="385"|'''Description'''
 +
| align="center" width="70"|'''Equivalent<br />IP Ratings'''
 +
|- class="tblBody"
 +
| align="center"|1
 +
| align="left"|Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt).
 +
| align="center"|IP 10
 +
|- class="tblBody"
 +
| align="center"|2
 +
| align="left"|Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
 +
| align="center"|IP 11
 +
|- class="tblBody"
 +
| align="center"|3
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 54
 +
|- class="tblBody"
 +
| align="center"|3R
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 14
 +
|- class="tblBody"
 +
| align="center"|3S
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and for which the external mechanism(s) remain operable when ice laden.
 +
| align="center"|IP 54
 +
|- class="tblBody"
 +
| align="center"|3X
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 54
 +
|- class="tblBody"
 +
| align="center"|3RX
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that will be undamaged by the external formation of ice on the enclosure that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 14
 +
|- class="tblBody"
 +
| align="center"|3SX
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion; and for which the external mechanism(s) remain operable when ice laden.
 +
| align="center"|IP 54
 +
|- class="tblBody"
 +
| align="center"|4
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 65
 +
|- class="tblBody"
 +
| align="center"|4X
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 65
 +
|- class="tblBody"
 +
| align="center"|5
 +
| align="left"|Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and settling airborne dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
 +
| align="center"|IP 52
 +
|- class="tblBody"
 +
| align="center"|6
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during occasional temporary submersion at a limited depth); and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 67
 +
|- class="tblBody"
 +
| align="center"|6P
 +
| align="left"|Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during prolonged submersion at a limited depth); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.
 +
| align="center"|IP 67
 +
|- class="tblBody"
 +
| align="center"|7
 +
| align="left"|Enclosures constructed for indoor use in hazardous (classified) locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70.
 +
| align="center"|--
 +
|- class="tblBody"
 +
| align="center"|8
 +
| align="left"|Enclosures constructed for either indoor or outdoor use in hazardous (classified) locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70.
 +
| align="center"|--
 +
|- class="tblBody"
 +
| align="center"|9
 +
| align="left"|Enclosures constructed for indoor use in hazardous (classified) locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA 70.
 +
| align="center"|--
 +
|- class="tblBody"
 +
| align="center"|10
 +
| align="left"|Enclosures constructed to meet the requirements of the Mine Safety and Health Administration, 30 CFR, Part 18.
 +
| align="center"|--
 +
|- class="tblBody"
 +
| align="center"|12
 +
| align="left"|Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
 +
| align="center"|IP 52
 +
|- class="tblBody"
 +
| align="center"|12K
 +
| align="left"|Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
 +
| align="center"|IP 52
 +
|- class="tblBody"
 +
| align="center"|13
 +
| align="left"|Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing); and to provide a degree of protection against the spraying, splashing, and seepage of oil and non-corrosive coolants.
 +
| align="center"|IP 54
 +
|}
 +
  
 
IK ratings goes from 00 to 10 and Dahua products are usually always IK10.
 
IK ratings goes from 00 to 10 and Dahua products are usually always IK10.
 
Below are what each IK ratings mean.
 
Below are what each IK ratings mean.
IK00   Not protected  
+
IK00 Not protected
IK01   Protected against 0.14 joules impact.
+
IK01 Protected against 0.14 joules impact.
 +
 
 
             Equivalent to impact of 0.25 kg mass dropped from 56 mm above impacted surface.
 
             Equivalent to impact of 0.25 kg mass dropped from 56 mm above impacted surface.
IK02   Protected against 0.2 joules impact.
+
IK02 Protected against 0.2 joules impact.
 +
 
 
             Equivalent to impact of 0.25 kg mass dropped from 80 mm above impacted surface.  
 
             Equivalent to impact of 0.25 kg mass dropped from 80 mm above impacted surface.  
IK03   Protected against 0.35 joules impact.
+
IK03 Protected against 0.35 joules impact.
 +
 
 
             Equivalent to impact of 0.25 kg mass dropped from 140 mm above impacted surface.  
 
             Equivalent to impact of 0.25 kg mass dropped from 140 mm above impacted surface.  
IK04   Protected against 0.5 joules impact.
+
IK04 Protected against 0.5 joules impact.
 +
 
 
             Equivalent to impact of 0.25 kg mass dropped from 200 mm above impacted surface.  
 
             Equivalent to impact of 0.25 kg mass dropped from 200 mm above impacted surface.  
IK05   Protected against 0.7 joules impact.
+
IK05 Protected against 0.7 joules impact.
 +
 
 
             Equivalent to impact of 0.25 kg mass dropped from 280 mm above impacted surface.
 
             Equivalent to impact of 0.25 kg mass dropped from 280 mm above impacted surface.
IK06   Protected against 1 joules impact.
+
IK06 Protected against 1 joules impact.
 +
 
 
             Equivalent to impact of 0.25 kg mass dropped from 400 mm above impacted surface.  
 
             Equivalent to impact of 0.25 kg mass dropped from 400 mm above impacted surface.  
IK07   Protected against 2 joules impact.
+
IK07 Protected against 2 joules impact.
 +
 
 
             Equivalent to impact of 0.5 kg mass dropped from 400 mm above impacted surface.  
 
             Equivalent to impact of 0.5 kg mass dropped from 400 mm above impacted surface.  
IK08   Protected against 5 joules impact.
+
IK08 Protected against 5 joules impact.
 +
 
 
             Equivalent to impact of 1.7 kg mass dropped from 300 mm above impacted surface.  
 
             Equivalent to impact of 1.7 kg mass dropped from 300 mm above impacted surface.  
IK09   Protected against 10 joules impact.
+
IK09 Protected against 10 joules impact.
 +
 
 
             Equivalent to impact of 5 kg mass dropped from 200 mm above impacted surface.  
 
             Equivalent to impact of 5 kg mass dropped from 200 mm above impacted surface.  
IK10   Protected against 20 joules impact.
+
IK10 Protected against 20 joules impact.
 +
 
 
             Equivalent to impact of 5 kg mass dropped from 400 mm above impacted surface.  
 
             Equivalent to impact of 5 kg mass dropped from 400 mm above impacted surface.  
  
 
[[Category:Troubleshoot]]
 
[[Category:Troubleshoot]]

Revision as of 21:00, 11 May 2016

What is IP, NEMA, and IK Ratings?

IP rating consists of 2 numbers, which is a standard for ingress protection. Dahua products are usually IP67.

IPrating.png

NEMA rating is the same as IP except their numbers goes from 1 to 13 with R,S,X,K as variations.


NEMA
Ratings
Description Equivalent
IP Ratings
1 Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts and to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt). IP 10
2 Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). IP 11
3 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. IP 54
3R Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. IP 14
3S Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and for which the external mechanism(s) remain operable when ice laden. IP 54
3X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure. IP 54
3RX Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that will be undamaged by the external formation of ice on the enclosure that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. IP 14
3SX Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion; and for which the external mechanism(s) remain operable when ice laden. IP 54
4 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure. IP 65
4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. IP 65
5 Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and settling airborne dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). IP 52
6 Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during occasional temporary submersion at a limited depth); and that will be undamaged by the external formation of ice on the enclosure. IP 67
6P Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (hose directed water and the entry of water during prolonged submersion at a limited depth); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure. IP 67
7 Enclosures constructed for indoor use in hazardous (classified) locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA 70. --
8 Enclosures constructed for either indoor or outdoor use in hazardous (classified) locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA 70. --
9 Enclosures constructed for indoor use in hazardous (classified) locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA 70. --
10 Enclosures constructed to meet the requirements of the Mine Safety and Health Administration, 30 CFR, Part 18. --
12 Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). IP 52
12K Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing). IP 52
13 Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing); and to provide a degree of protection against the spraying, splashing, and seepage of oil and non-corrosive coolants. IP 54


IK ratings goes from 00 to 10 and Dahua products are usually always IK10. Below are what each IK ratings mean. IK00 Not protected IK01 Protected against 0.14 joules impact.

           Equivalent to impact of 0.25 kg mass dropped from 56 mm above impacted surface.

IK02 Protected against 0.2 joules impact.

           Equivalent to impact of 0.25 kg mass dropped from 80 mm above impacted surface. 

IK03 Protected against 0.35 joules impact.

           Equivalent to impact of 0.25 kg mass dropped from 140 mm above impacted surface. 

IK04 Protected against 0.5 joules impact.

           Equivalent to impact of 0.25 kg mass dropped from 200 mm above impacted surface. 

IK05 Protected against 0.7 joules impact.

           Equivalent to impact of 0.25 kg mass dropped from 280 mm above impacted surface.

IK06 Protected against 1 joules impact.

           Equivalent to impact of 0.25 kg mass dropped from 400 mm above impacted surface. 

IK07 Protected against 2 joules impact.

           Equivalent to impact of 0.5 kg mass dropped from 400 mm above impacted surface. 

IK08 Protected against 5 joules impact.

           Equivalent to impact of 1.7 kg mass dropped from 300 mm above impacted surface. 

IK09 Protected against 10 joules impact.

           Equivalent to impact of 5 kg mass dropped from 200 mm above impacted surface. 

IK10 Protected against 20 joules impact.

           Equivalent to impact of 5 kg mass dropped from 400 mm above impacted surface.