Notice: Firmware Links Under Maintenance We are currently undergoing maintenance on all firmware links. If any links are inaccessible, please email or contact Tech Support for the firmware. We appreciate your patience during the maintenance, thank you for your understanding.

Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

Line 1: Line 1:
 
=Alarm Input and Output=
 
=Alarm Input and Output=
 
==Cable Connections==
 
==Cable Connections==
 +
*Alarm1 = Normal
 +
*Alarm2 = High Temp
 +
*No alert for mask or face detection currently.
 
===Contact 1===
 
===Contact 1===
 
{| class="wikitable"
 
{| class="wikitable"

Revision as of 17:16, 18 June 2020

Alarm Input and Output

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black RD– Negative electrode of external card reader.
Red RD+ Positive electrode of external card reader.
Blue CASE Tamper alarm input of the external card reader.
White D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown LED Connected to external reader indicator in
Yellow B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red ALARM1_NO Alarm 1 normally open output port
White and orange ALARM1_COM Alarm 1 common output port.
White and blue ALARM2_NO Alarm 2 normally open output port.
White and gray ALARM2_COM Alarm 2 common output port.
White and green GND Connected to the common GND port.
White Brown ALARM1 Alarm 1 input port.
White and yellow GND Connected to the common GND port.
White and purple ALARM2 Alarm 2 input port.