Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

(Contact 3)
Line 2: Line 2:
 
[[file:DHI-ASI7213X-T1_Cable_Connections.png|thumb|Cable Connections]]
 
[[file:DHI-ASI7213X-T1_Cable_Connections.png|thumb|Cable Connections]]
 
[[file:DHI-ASI7213X-T1_Physical_Setup.png|thumb|Physical Setup]]
 
[[file:DHI-ASI7213X-T1_Physical_Setup.png|thumb|Physical Setup]]
 +
==Web Interface==
 +
<gallery mode="packed-hover">
 +
File:DHI-ASI7213X-T1_Alarm_Linkage_WebUI.png
 +
File:DHI-ASI7213X-T1_Alarm_Linkage_Log_WebUI.png
 +
</gallery>
 +
===Alarm Linkage===
 +
 +
  
 
==Cable Connections==
 
==Cable Connections==

Revision as of 19:49, 18 June 2020

Alarm Input and Output

Cable Connections
Physical Setup

Web Interface

Alarm Linkage

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black Wire black.svg RD– Negative electrode of external card reader.
Red 35px RD+ Positive electrode of external card reader.
Blue 35px CASE Tamper alarm input of the external card reader.
White Wire white.svg D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green 35px D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown 35px LED Connected to external reader indicator in
Yellow File:Wire yellow.svg B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red 35px ALARM1_NO Alarm 1 normally open output port
White and orange Wire white orange stripe.svg ALARM1_COM Alarm 1 common output port.
White and blue 35px ALARM2_NO Alarm 2 normally open output port.
White and gray Wire white gray stripe.svg ALARM2_COM Alarm 2 common output port.
White and green Wire white green stripe.svg GND Connected to the common GND port.
White Brown 35px ALARM1 Alarm 1 input port.
White and yellow 35px GND Connected to the common GND port.
White and purple Wire white purple stripe.png ALARM2 Alarm 2 input port.

Contact 3

Port Cable Color Cable Name Description
CON3
CON3
Black and red 35px RX RS-232 receiving port.
Black and orange 35px TX RS-232 sending port.
Black and blue 35px GND Connected to the common GND port.
Black and gray 35px SR1 Used for door contact detection.
Black and green File:Wire black green stripe.svg PUSH1 Door open button of door No.1
Black and brown 35px DOOR1_COM Lock control common port.
Black and yellow 35px DOOR1_NO Lock control normally open port.
Black and purple Wire black purple stripe.png DOOR1_NC Lock control normally closed port.