Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

(Web Interface)
(Web Interface)
Line 3: Line 3:
 
[[file:DHI-ASI7213X-T1_Physical_Setup.png|thumb|Physical Setup]]
 
[[file:DHI-ASI7213X-T1_Physical_Setup.png|thumb|Physical Setup]]
 
==Web Interface==
 
==Web Interface==
<gallery mode="packed-hover">
+
<gallery>
 
File:DHI-ASI7213X-T1_Alarm_Linkage_WebUI.png|''Alarm Linkage''
 
File:DHI-ASI7213X-T1_Alarm_Linkage_WebUI.png|''Alarm Linkage''
File:DHI-ASI7213X-T1_Alarm_Linkage_Log_WebUI.png
+
File:DHI-ASI7213X-T1_Alarm_Linkage_Log_WebUI.png|''Alarm Linkage Log''
 
</gallery>
 
</gallery>
 
===Alarm Linkage===
 
===Alarm Linkage===

Revision as of 19:50, 18 June 2020

Alarm Input and Output

Cable Connections
Physical Setup

Web Interface

Alarm Linkage

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black Wire black.svg RD– Negative electrode of external card reader.
Red Wire red.svg RD+ Positive electrode of external card reader.
Blue Wire blue.svg CASE Tamper alarm input of the external card reader.
White Wire white.svg D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green Wire green.svg D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown Wire brown.svg LED Connected to external reader indicator in
Yellow Wire yellow.svg B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red Wire white red stripe.svg ALARM1_NO Alarm 1 normally open output port
White and orange Wire white orange stripe.svg ALARM1_COM Alarm 1 common output port.
White and blue Wire white blue stripe.svg ALARM2_NO Alarm 2 normally open output port.
White and gray Wire white gray stripe.svg ALARM2_COM Alarm 2 common output port.
White and green Wire white green stripe.svg GND Connected to the common GND port.
White Brown Wire white brown stripe.svg ALARM1 Alarm 1 input port.
White and yellow Wire white yellow stripe.svg GND Connected to the common GND port.
White and purple Wire white purple stripe.png ALARM2 Alarm 2 input port.

Contact 3

Port Cable Color Cable Name Description
CON3
CON3
Black and red Wire black red stripe.svg RX RS-232 receiving port.
Black and orange Wire black orange stripe.svg TX RS-232 sending port.
Black and blue Wire black blue stripe.svg GND Connected to the common GND port.
Black and gray Wire black gray stripe.svg SR1 Used for door contact detection.
Black and green Wire black green stripe.svg PUSH1 Door open button of door No.1
Black and brown Wire black brown stripe.svg DOOR1_COM Lock control common port.
Black and yellow Wire black yellow stripe.svg DOOR1_NO Lock control normally open port.
Black and purple Wire black purple stripe.png DOOR1_NC Lock control normally closed port.