Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

(Door Strike and Door Release Button Physical Setup)
(Normal Body Temperature Indication Light)
Line 188: Line 188:
 
|ALARM1_NO
 
|ALARM1_NO
 
|Alarm 1 normally open output port
 
|Alarm 1 normally open output port
|-
 
|White and orange
 
|[[File:Wire_white_orange_stripe.svg|35px]]
 
|ALARM1_COM
 
|Alarm 1 common output port.
 
|-
 
|White and blue
 
|[[File:Wire_white_blue_stripe.svg|35px]]
 
|ALARM2_NO
 
|Alarm 2 normally open output port.
 
 
|-
 
|-
 
|White and gray
 
|White and gray
Line 203: Line 193:
 
|ALARM2_COM
 
|ALARM2_COM
 
|Alarm 2 common output port.
 
|Alarm 2 common output port.
|-
 
|White and green
 
|[[File:Wire_white_green_stripe.svg|35px]]
 
|GND
 
|Connected to the common GND port.
 
|-
 
|White Brown
 
|[[File:Wire_white_brown_stripe.svg|35px]]
 
|ALARM1
 
|Alarm 1 input port.
 
|-
 
|White and yellow
 
|[[File:Wire_white_yellow_stripe.svg|35px]]
 
|GND
 
|Connected to the common GND port.
 
|-
 
|White and purple
 
|[[file:Wire_white_purple_stripe.png|35px]]
 
|ALARM2
 
|Alarm 2 input port.
 
 
|}
 
|}
  

Revision as of 15:33, 19 June 2020

Alarm Input and Output

Cable Connections
Physical Setup

Web Interface

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black Wire black.svg RD– Negative electrode of external card reader.
Red File:Wire red.svg RD+ Positive electrode of external card reader.
Blue File:Wire blue.svg CASE Tamper alarm input of the external card reader.
White 35px D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green 35px D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown 35px LED Connected to external reader indicator in
Yellow 35px B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red 35px ALARM1_NO Alarm 1 normally open output port
White and orange File:Wire white orange stripe.svg ALARM1_COM Alarm 1 common output port.
White and blue 35px ALARM2_NO Alarm 2 normally open output port.
White and gray 35px ALARM2_COM Alarm 2 common output port.
White and green 35px GND Connected to the common GND port.
White Brown 35px ALARM1 Alarm 1 input port.
White and yellow 35px GND Connected to the common GND port.
White and purple Wire white purple stripe.png ALARM2 Alarm 2 input port.

Contact 3

Port Cable Color Cable Name Description
CON3
CON3
Black and red Wire black red stripe.svg RX RS-232 receiving port.
Black and orange 35px TX RS-232 sending port.
Black and blue 35px GND Connected to the common GND port.
Black and gray 35px SR1 Used for door contact detection.
Black and green 35px PUSH1 Door open button of door No.1
Black and brown 35px DOOR1_COM Lock control common port.
Black and yellow 35px DOOR1_NO Lock control normally open port.
Black and purple Wire black purple stripe.png DOOR1_NC Lock control normally closed port.

Normal Body Temperature Indication Light

Port Cable Color Cable Name Description
CON2
CON2
White and red 35px ALARM1_NO Alarm 1 normally open output port
White and gray 35px ALARM2_COM Alarm 2 common output port.

High Body Temperature Indication Light

Port Cable Color Cable Name Description
CON2
CON2
White and red 35px ALARM1_NO Alarm 1 normally open output port
White and orange File:Wire white orange stripe.svg ALARM1_COM Alarm 1 common output port.
White and blue 35px ALARM2_NO Alarm 2 normally open output port.
White and gray 35px ALARM2_COM Alarm 2 common output port.
White and green 35px GND Connected to the common GND port.
White Brown 35px ALARM1 Alarm 1 input port.
White and yellow 35px GND Connected to the common GND port.
White and purple Wire white purple stripe.png ALARM2 Alarm 2 input port.

Door Strike and Door Release Button Physical Setup

Port Cable Color Cable Name Description
CON3
CON3
Black and red Wire black red stripe.svg RX RS-232 receiving port.
Black and orange 35px TX RS-232 sending port.
Black and blue 35px GND Connected to the common GND port.
Black and gray 35px SR1 Used for door contact detection.
Black and green 35px PUSH1 Door open button of door No.1
Black and brown 35px DOOR1_COM Lock control common port.
Black and yellow 35px DOOR1_NO Lock control normally open port.
Black and purple Wire black purple stripe.png DOOR1_NC Lock control normally closed port.