Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Door Release Button Physical Setup) |
|||
Line 269: | Line 269: | ||
|} | |} | ||
<embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | <embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | ||
+ | ==Card Reader:RS485== | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON1 | ||
+ | |- | ||
+ | |rowspan="9"|CON1 | ||
+ | |- | ||
+ | |Yellow | ||
+ | |[[File:Wire_yellow.svg|35px]] | ||
+ | |B | ||
+ | |RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
+ | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
+ | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid. | ||
+ | |- | ||
+ | |Purple | ||
+ | |[[File:Wire_purple.png|35px]] | ||
+ | |A | ||
+ | |RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
+ | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
+ | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid | ||
+ | |} | ||
+ | ==Card Reader:Wiegand== | ||
+ | {| class="wikitable" | ||
+ | !|Port | ||
+ | !colspan="2"|Cable Color | ||
+ | !|Cable Name | ||
+ | !|Description | ||
+ | |- | ||
+ | |+CON1 | ||
+ | |- | ||
+ | |rowspan="9"|CON1 | ||
+ | |- | ||
+ | |White | ||
+ | |[[File:Wire_white.svg|35px]] | ||
+ | |D1 | ||
+ | |Wiegand D1 input (connected to external card reader)/output (connected to controller). | ||
+ | |- | ||
+ | |Green | ||
+ | |[[File:Wire_green.svg|35px]] | ||
+ | |D0 | ||
+ | |Wiegand D0 input (connected to external card reader)/output (connected to controller). | ||
+ | |- | ||
+ | |} | ||
+ | |||
==WebUI Alarm Setup== | ==WebUI Alarm Setup== | ||
<embedvideo service="youtube">https://youtu.be/vjfoiNMyOB8</embedvideo> | <embedvideo service="youtube">https://youtu.be/vjfoiNMyOB8</embedvideo> | ||
==SystemUI Set Temperature Threshold== | ==SystemUI Set Temperature Threshold== | ||
<embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> | <embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> |
Revision as of 21:07, 19 June 2020
Contents
- 1 Alarm Input and Output
- 1.1 Web Interface
- 1.2 Cable Connections
- 1.3 Normal Body Temperature Indication Light
- 1.4 High Body Temperature Indication Light
- 1.5 Door Strike Physical Setup
- 1.6 Door Release Button Physical Setup
- 1.7 Card Reader:RS485
- 1.8 Card Reader:Wiegand
- 1.9 WebUI Alarm Setup
- 1.10 SystemUI Set Temperature Threshold
Alarm Input and Output
Web Interface
Cable Connections
- Alarm1 = Normal
- Alarm2 = High Temp
- No alert for mask or face detection currently.
Contact 1
Contact 2
Contact 3
Normal Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and red | ALARM1_NO | Alarm 1 normally open output port | ||
White and orange | ALARM1_COM | Alarm 1 common output port. |
High Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and blue | ALARM2_NO | Alarm 2 normally open output port. | ||
White and gray | ALARM2_COM | Alarm 2 common output port. |
Door Strike Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and brown | DOOR1_COM | Lock control common port. | ||
Black and purple | DOOR1_NC | Lock control normally closed port. |
Door Release Button Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and blue | GND | Connected to the common GND port. | ||
Black and green | PUSH1 | Door open button of door No.1 |