Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Door Release Button Physical Setup) |
|||
| Line 269: | Line 269: | ||
|} | |} | ||
<embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | <embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | ||
| + | ==Card Reader:RS485== | ||
| + | {| class="wikitable" | ||
| + | !|Port | ||
| + | !colspan="2"|Cable Color | ||
| + | !|Cable Name | ||
| + | !|Description | ||
| + | |- | ||
| + | |+CON1 | ||
| + | |- | ||
| + | |rowspan="9"|CON1 | ||
| + | |- | ||
| + | |Yellow | ||
| + | |[[File:Wire_yellow.svg|35px]] | ||
| + | |B | ||
| + | |RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
| + | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
| + | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid. | ||
| + | |- | ||
| + | |Purple | ||
| + | |[[File:Wire_purple.png|35px]] | ||
| + | |A | ||
| + | |RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
| + | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
| + | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid | ||
| + | |} | ||
| + | ==Card Reader:Wiegand== | ||
| + | {| class="wikitable" | ||
| + | !|Port | ||
| + | !colspan="2"|Cable Color | ||
| + | !|Cable Name | ||
| + | !|Description | ||
| + | |- | ||
| + | |+CON1 | ||
| + | |- | ||
| + | |rowspan="9"|CON1 | ||
| + | |- | ||
| + | |White | ||
| + | |[[File:Wire_white.svg|35px]] | ||
| + | |D1 | ||
| + | |Wiegand D1 input (connected to external card reader)/output (connected to controller). | ||
| + | |- | ||
| + | |Green | ||
| + | |[[File:Wire_green.svg|35px]] | ||
| + | |D0 | ||
| + | |Wiegand D0 input (connected to external card reader)/output (connected to controller). | ||
| + | |- | ||
| + | |} | ||
| + | |||
==WebUI Alarm Setup== | ==WebUI Alarm Setup== | ||
<embedvideo service="youtube">https://youtu.be/vjfoiNMyOB8</embedvideo> | <embedvideo service="youtube">https://youtu.be/vjfoiNMyOB8</embedvideo> | ||
==SystemUI Set Temperature Threshold== | ==SystemUI Set Temperature Threshold== | ||
<embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> | <embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> | ||
Revision as of 21:07, 19 June 2020
Contents
- 1 Alarm Input and Output
- 1.1 Web Interface
- 1.2 Cable Connections
- 1.3 Normal Body Temperature Indication Light
- 1.4 High Body Temperature Indication Light
- 1.5 Door Strike Physical Setup
- 1.6 Door Release Button Physical Setup
- 1.7 Card Reader:RS485
- 1.8 Card Reader:Wiegand
- 1.9 WebUI Alarm Setup
- 1.10 SystemUI Set Temperature Threshold
Alarm Input and Output
Web Interface
Cable Connections
- Alarm1 = Normal
- Alarm2 = High Temp
- No alert for mask or face detection currently.
Contact 1
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON1 | ||||
| Black | 35px | RD– | Negative electrode of external card reader. | |
| Red | 35px | RD+ | Positive electrode of external card reader. | |
| Blue | 35px | CASE | Tamper alarm input of the external card reader. | |
| White | 35px | D1 | Wiegand D1 input (connected to external card reader)/output (connected to controller). | |
| Green | 35px | D0 | Wiegand D0 input (connected to external card reader)/output (connected to controller). | |
| Brown | 35px | LED | Connected to external reader indicator in | |
| Yellow | 35px | B | RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| |
| Purple | A | RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| ||
Contact 2
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON2 | ||||
| White and red | File:Wire white red stripe.svg | ALARM1_NO | Alarm 1 normally open output port | |
| White and orange | File:Wire white orange stripe.svg | ALARM1_COM | Alarm 1 common output port. | |
| White and blue | File:Wire white blue stripe.svg | ALARM2_NO | Alarm 2 normally open output port. | |
| White and gray | 35px | ALARM2_COM | Alarm 2 common output port. | |
| White and green | 35px | GND | Connected to the common GND port. | |
| White Brown | File:Wire white brown stripe.svg | ALARM1 | Alarm 1 input port. | |
| White and yellow | 35px | GND | Connected to the common GND port. | |
| White and purple | ALARM2 | Alarm 2 input port. | ||
Contact 3
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON3 | ||||
| Black and red | 35px | RX | RS-232 receiving port. | |
| Black and orange | 35px | TX | RS-232 sending port. | |
| Black and blue | 35px | GND | Connected to the common GND port. | |
| Black and gray | File:Wire black gray stripe.svg | SR1 | Used for door contact detection. | |
| Black and green | 35px | PUSH1 | Door open button of door No.1 | |
| Black and brown | 35px | DOOR1_COM | Lock control common port. | |
| Black and yellow | File:Wire black yellow stripe.svg | DOOR1_NO | Lock control normally open port. | |
| Black and purple | DOOR1_NC | Lock control normally closed port. | ||
Normal Body Temperature Indication Light
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON2 | ||||
| White and red | File:Wire white red stripe.svg | ALARM1_NO | Alarm 1 normally open output port | |
| White and orange | File:Wire white orange stripe.svg | ALARM1_COM | Alarm 1 common output port. | |
High Body Temperature Indication Light
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON2 | ||||
| White and blue | File:Wire white blue stripe.svg | ALARM2_NO | Alarm 2 normally open output port. | |
| White and gray | 35px | ALARM2_COM | Alarm 2 common output port. | |
Door Strike Physical Setup
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON3 | ||||
| Black and brown | 35px | DOOR1_COM | Lock control common port. | |
| Black and purple | DOOR1_NC | Lock control normally closed port. | ||
Door Release Button Physical Setup
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON3 | ||||
| Black and blue | 35px | GND | Connected to the common GND port. | |
| Black and green | 35px | PUSH1 | Door open button of door No.1 | |
Card Reader:RS485
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON1 | ||||
| Yellow | 35px | B | RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| |
| Purple | A | RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| ||
Card Reader:Wiegand
| Port | Cable Color | Cable Name | Description | |
|---|---|---|---|---|
| CON1 | ||||
| White | 35px | D1 | Wiegand D1 input (connected to external card reader)/output (connected to controller). | |
| Green | 35px | D0 | Wiegand D0 input (connected to external card reader)/output (connected to controller). | |