Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

(Card Reader:RS485)
(Contact 3)
Line 138: Line 138:
 
|-
 
|-
 
|rowspan="9"|CON3
 
|rowspan="9"|CON3
|-
 
|Black and red
 
|[[File:Wire_black_red_stripe.svg|35px]]
 
|RX
 
|RS-232 receiving port.
 
|-
 
|Black and orange
 
|[[File:Wire_black_orange_stripe.svg|35px]]
 
|TX
 
|RS-232 sending port.
 
 
|-
 
|-
 
|Black and blue
 
|Black and blue
Line 179: Line 169:
 
|Lock control normally closed port.
 
|Lock control normally closed port.
 
|}
 
|}
 +
 
==Normal Body Temperature Indication Light==
 
==Normal Body Temperature Indication Light==
 
[[File:Normal Temp alarm Setup.png|700px|right]]
 
[[File:Normal Temp alarm Setup.png|700px|right]]

Revision as of 17:22, 30 June 2020

Alarm Input and Output

Cable Connections
Physical Setup


DHI-ASI7213X-T1 Contacts Reference Sheet

Web Interface

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black 35px RD– Negative electrode of external card reader.
Red 35px RD+ Positive electrode of external card reader.
Blue 35px CASE Tamper alarm input of the external card reader.
White 35px D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green File:Wire green.svg D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown 35px LED Connected to external reader indicator in
Yellow 35px B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red Wire white red stripe.svg ALARM1_NO Alarm 1 normally open output port
White and orange 35px ALARM1_COM Alarm 1 common output port.
White and blue 35px ALARM2_NO Alarm 2 normally open output port.
White and gray 35px ALARM2_COM Alarm 2 common output port.
White and green 35px GND Connected to the common GND port.
White Brown 35px ALARM1 Alarm 1 input port.
White and yellow 35px GND Connected to the common GND port.
White and purple Wire white purple stripe.png ALARM2 Alarm 2 input port.

Contact 3

Port Cable Color Cable Name Description
CON3
CON3
Black and blue File:Wire black blue stripe.svg GND Connected to the common GND port.
Black and gray 35px SR1 Used for door contact detection.
Black and green Wire black green stripe.svg PUSH1 Door open button of door No.1
Black and brown File:Wire black brown stripe.svg DOOR1_COM Lock control common port.
Black and yellow 35px DOOR1_NO Lock control normally open port.
Black and purple Wire black purple stripe.png DOOR1_NC Lock control normally closed port.

Normal Body Temperature Indication Light

Normal Temp alarm Setup.png
Port Cable Color Cable Name Description
CON2
CON2
White and red Wire white red stripe.svg ALARM1_NO Alarm 1 normally open output port
White and orange 35px ALARM1_COM Alarm 1 common output port.

High Body Temperature Indication Light

High Temp Alarm Setup.png
Port Cable Color Cable Name Description
CON2
CON2
White and blue 35px ALARM2_NO Alarm 2 normally open output port.
White and gray 35px ALARM2_COM Alarm 2 common output port.

Door Strike Physical Setup

Door Strike Physical Setup.png
Port Cable Color Cable Name Description
CON3
CON3
Black and brown File:Wire black brown stripe.svg DOOR1_COM Lock control common port.
Black and purple Wire black purple stripe.png DOOR1_NC Lock control normally closed port.

Door Release Button Physical Setup

Door Release Button Physical Setup.png
Port Cable Color Cable Name Description
CON3
CON3
Black and blue Wire black blue stripe.svg GND Connected to the common GND port.
Black and green Wire black green stripe.svg PUSH1 Door open button of door No.1

Card Reader:RS485

Port Cable Color Cable Name Description
CON1
CON1
Yellow 35px B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple Wire purple.png A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Card Reader:Wiegand

Port Cable Color Cable Name Description
CON1
CON1
White 35px D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green Wire green.svg D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).

WebUI Alarm Setup