Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Normal Body Temperature or No Mask Indication Light) |
|||
Line 397: | Line 397: | ||
==SystemUI Set Temperature Threshold== | ==SystemUI Set Temperature Threshold== | ||
<embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> | <embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> | ||
+ | |||
+ | ==Notes== | ||
+ | *Access Link Enable is only used when a door is configured for access for normal temperature. If the Kiosk is only used for LED lights, this option shouldn't be enabled. |
Latest revision as of 15:44, 9 July 2021
Contents
- 1 Alarm Input and Output
- 1.1 Web Interface
- 1.2 Cable Connections
- 1.3 Alarm Outputs 1 and 2 - New Firmware
- 1.4 Alarm Outputs 1 and 2 - Old Firmware
- 1.5 Door Strike Physical Setup
- 1.6 Door Release Button Physical Setup
- 1.7 Card Reader:RS485
- 1.8 Card Reader:Wiegand
- 1.9 WebUI Alarm Setup
- 1.10 SystemUI Set Temperature Threshold
- 1.11 Notes
Alarm Input and Output
Web Interface
Cable Connections
- Alarm1 = High Temp
- Alarm2 = Normal Temp or No Mask
- No alert for face detection currently.
Contact 1
Contact 2
Contact 3
Alarm Outputs 1 and 2 - New Firmware
PLEASE NOTE: These instructions are for Alarm Outputs 1 and 2 on firmware version 1.000.10BE001.0.R.200722 and later |
---|
High Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and red | ALARM1_NO | Alarm 1 normally open output port | ||
White and orange | ALARM1_COM | Alarm 1 common output port. |
Normal Body Temperature or No Mask Indication Light
PLEASE NOTE: On firmware version 1.000.10BE001.0.R.200722 and later, you must set the Alarm Output 2 mode setting to either "Normal Temperature Alarm" for being triggered when a normal temperature is detected or "No Mask Alarm" for being triggered when no mask is detected |
---|
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and blue | ALARM2_NO | Alarm 2 normally open output port. | ||
White and gray | ALARM2_COM | Alarm 2 common output port. |
Alarm Outputs 1 and 2 - Old Firmware
PLEASE NOTE: These instructions are for Alarm Outputs 1 and 2 on firmware older than version 1.000.10BE001.0.R.200722 |
---|
High Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and blue | ALARM2_NO | Alarm 2 normally open output port. | ||
White and gray | ALARM2_COM | Alarm 2 common output port. |
Normal Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and red | ALARM1_NO | Alarm 1 normally open output port | ||
White and orange | ALARM1_COM | Alarm 1 common output port. |
Door Strike Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and brown | DOOR1_COM | Lock control common port. | ||
Black and purple | DOOR1_NC | Lock control normally closed port. |
Door Release Button Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and blue | GND | Connected to the common GND port. | ||
Black and green | PUSH1 | Door open button of door No.1 |
Card Reader:RS485
Card Reader:Wiegand
WebUI Alarm Setup
SystemUI Set Temperature Threshold
Notes