Alarm COnnection
Alarm Port
The alarm port is shown as below. The following figure is based on the 78 series.
Icon |
Function |
1~16 |
ALARM1~ALARM16. The alarm becomes activated in the low level. |
NO1 C1,NO2 C2,NO3 C3,NO4 C4 |
Four NO activation output groups. (On-off button). |
NO5 C5 NC5 |
One NO/NC activation output group. (On-off button). |
CTRL 12V |
Control power output. Disable power output when alarm is canceled. Current is 500mA. |
+12V |
Rated current output. Current is 500mA. |
GND | |
A/B |
485 communication port. They are used to control devices such as PTZ. Please parallel connect 120TΩ between A/B cables if there are too many PTZ decoders. |