Difference between revisions of ":People Counting"

(Camera Mounting and Best Practices)
(Camera Mounting and IVS Best Practices)
Line 9: Line 9:
 
*IVS capable devices
 
*IVS capable devices
 
*Current Firmware
 
*Current Firmware
===Camera Mounting and IVS Best Practices===
+
===Installation Requirements===
  
 
[[File:IVS_people_counting_Camera_mounting_1.jpg|600x600px]]
 
[[File:IVS_people_counting_Camera_mounting_1.jpg|600x600px]]
Line 15: Line 15:
 
The reason this example works better is that the scene is not as complicated as a horizontal shot. This provides a stable and clear background to differentiate object detection (shown as a green box around the targets) from a static object. '''If the background is a complicated scene, like a horizontal camera shot outdoors, then the camera loses the efficiency of detecting a moving object.''' This results in the People Counting IVS rule (seen as a blue box) not reliably triggering.
 
The reason this example works better is that the scene is not as complicated as a horizontal shot. This provides a stable and clear background to differentiate object detection (shown as a green box around the targets) from a static object. '''If the background is a complicated scene, like a horizontal camera shot outdoors, then the camera loses the efficiency of detecting a moving object.''' This results in the People Counting IVS rule (seen as a blue box) not reliably triggering.
 
The camera should be mounted at least 9 feet above the target if using a 3.6mm lens. Using a camera with a varifocal lens can help create a better scene if mounting options are limited. Adjusting the image settings: contrast, B&W, and gamma can aid in getting better detection, but will reduce image quality. To assess issues with IVS compatibility between the camera and NVR, please update both devices to the most current firmware and factory reset the NVR, and use the hard reset button to reset the camera.
 
The camera should be mounted at least 9 feet above the target if using a 3.6mm lens. Using a camera with a varifocal lens can help create a better scene if mounting options are limited. Adjusting the image settings: contrast, B&W, and gamma can aid in getting better detection, but will reduce image quality. To assess issues with IVS compatibility between the camera and NVR, please update both devices to the most current firmware and factory reset the NVR, and use the hard reset button to reset the camera.
 +
 +
====Height Requirements====
 +
1. Vari-focal (H > 2.8 meters): vari-focal device is recommended to make people counting statistics
 +
 +
2. Fixed focal (only for reference):
 +
 +
{| class="wikitable"
 +
|Resolution
 +
|f(mm)
 +
|H(m)
 +
|-
 +
|2MP
 +
|2.8
 +
|2.8
 +
|-
 +
|2MP
 +
|3.6
 +
|3
 +
|}
  
 
===Video Instructions===
 
===Video Instructions===

Revision as of 19:36, 12 March 2018

People Counting

Description

It is to make statistics of enter and leave people in the specific area of the image, and finally it comes out the statistics data, providing kinds of data reports such as day report, month report and year report. There are two ways to present: line chart and bar chart, providing data exporting function.

Note: People counting supports max half year data, it will operate auto overwrite according to hour when surpassing one year.

Prerequisites

  • Internet Explorer
  • IP Address of Device
  • IVS capable devices
  • Current Firmware

Installation Requirements

IVS people counting Camera mounting 1.jpg

The reason this example works better is that the scene is not as complicated as a horizontal shot. This provides a stable and clear background to differentiate object detection (shown as a green box around the targets) from a static object. If the background is a complicated scene, like a horizontal camera shot outdoors, then the camera loses the efficiency of detecting a moving object. This results in the People Counting IVS rule (seen as a blue box) not reliably triggering. The camera should be mounted at least 9 feet above the target if using a 3.6mm lens. Using a camera with a varifocal lens can help create a better scene if mounting options are limited. Adjusting the image settings: contrast, B&W, and gamma can aid in getting better detection, but will reduce image quality. To assess issues with IVS compatibility between the camera and NVR, please update both devices to the most current firmware and factory reset the NVR, and use the hard reset button to reset the camera.

Height Requirements

1. Vari-focal (H > 2.8 meters): vari-focal device is recommended to make people counting statistics

2. Fixed focal (only for reference):

Resolution f(mm) H(m)
2MP 2.8 2.8
2MP 3.6 3

Video Instructions

Step by Step Instructions

1. Login to the camera you wish to enable People Counting on.

Error creating thumbnail: Unable to save thumbnail to destination

2. Click, "Setup"

PeopleCountingHowTo2.png

3. Then click, "Event"

Error creating thumbnail: Unable to save thumbnail to destination

4. Click, "People Counting"

Error creating thumbnail: Unable to save thumbnail to destination

5. Check the box for, "Enable"

PeopleCountingHowTo5.png

6. Click, "Draw Rule"

PeopleCountingHowTo6.png

7. Left click, and draw a region for where you want the camera to count people.

PeopleCountingHowTo7.png

8. Check the box for, "Enable OSD"

PeopleCountingHowTo8.png

9. Specify under what condition you want people to be counted by clicking the drop down to the right of, "Direction"

PeopleCountingHowTo9.png

10. Click, "Save" and then, "Live"

PeopleCountingHowTo10.png

11. If successful, your live feed should look like this.

PeopleCountingHowTo11.png

Line Chart

PeopleCountingHowTo12.png

Bar Chart

PeopleCountingHowTo13.png

Operation Steps:

  1. Enter report interface, select report type, such as day report, month report and year report.
  2. Select the time of statistics report.
  3. Select people counting direction of statistics and ways to present of the report including bar chart or line chart.
  4. Click Search button to view the report presentation.
  5. Click export to save report as CSV format or picture format.


System Interface Setup

Prerequisites

Video Instructions

Step by Step Instructions

Step by Step Instructions

1. Go to Events.

PeopleCountingSetupSystem1.png

2. Under Smart plan, select people counting and click apply.

PeopleCountingSetupSystem2.png

3. Under People counting, select enable then select Rules.

PeopleCountingSetupSystem3.png

4. Click on number stat, draw rules, and then click ok.

PeopleCountingSetupSystem4.png

5. Click apply.

PeopleCountingSetupSystem5.png

SmartPSS Setup

Prerequisites

  • SmartPSS 2.0
  • IVS capable device
  • Upgraded devices to latest firmware

Video Instructions

Step by Step Instructions for SmartPSS

1. Login into SmartPSS and select Live.

600px

2. Select People Counting capable device and rigct click to show IVS Channel Config.

600px

3. Select People Counting -> Select Next.

600px

4. Select Lens Direction. For this tutorial we are using vertical -> click on down arrow which will bring up Rules Details.

600px

5. Draw a rule

600px

6. Select Config. Here you can change the enter direction, enter number exit number and remaining number.

600px

7. Select Arming Schedule to set schedule.

600px

8. Select Aalarm to set type of alarm -> select save.

600px

9. Apply and save to save settings.

600px

10. Go back to the main menu and select People Counting.

600px

11. Select Device -> Select Search

600px

12. Here you can see the generated report.

600px