After I connected to the IP channel, there one*window output is OK, but there is no multiple*window output.
There are following possibilities:
- Check the sub stream of the camera has been enabled or not.
- Check the sub stream type of the camera is H.264 or not.
- Check the device supports camera sub stream resolution or not (such as 960H, D1, HD1 and etc.).