Difference between revisions of "PTZ/Instructions/RS485"
(→Determine PTZ's Address, Baud, & Protocol) |
(→New Template) |
||
| Line 9: | Line 9: | ||
*[[IPPTZ/Pelco_and_RS485|Pelco & RS485]] | *[[IPPTZ/Pelco_and_RS485|Pelco & RS485]] | ||
| + | ==Common RS485 Settings== | ||
| + | {| class="wikitable" | ||
| + | !|Device | ||
| + | !|Channel | ||
| + | !|PTZ Type: | ||
| + | !|Protocol | ||
| + | !|Address | ||
| + | !|Baud Rate | ||
| + | !|Data Bit | ||
| + | !|Stop Bit | ||
| + | !|Parity | ||
| + | |- | ||
| + | |Dahua SD59230IN-HC | ||
| + | |1 | ||
| + | |Local | ||
| + | |Pelco-D | ||
| + | |1 | ||
| + | |9600 | ||
| + | |8 | ||
| + | |1 | ||
| + | |None | ||
| + | |} | ||
==New Template== | ==New Template== | ||
1. Connect the RS485 cable of the PTZ camera to the RS485 port on the Device. Ensure the match of A and B interfaces. | 1. Connect the RS485 cable of the PTZ camera to the RS485 port on the Device. Ensure the match of A and B interfaces. | ||
Revision as of 17:07, 21 January 2020
Contents
RS485
Description
RS485 is a communication port which is based on coaxial cable. It can control the camera via back-end device when the information of RS485 is set in accordance with that of the back-end coding device.
Prerequisites
Instructions
Common RS485 Settings
| Device | Channel | PTZ Type: | Protocol | Address | Baud Rate | Data Bit | Stop Bit | Parity |
|---|---|---|---|---|---|---|---|---|
| Dahua SD59230IN-HC | 1 | Local | Pelco-D | 1 | 9600 | 8 | 1 | None |
New Template
1. Connect the RS485 cable of the PTZ camera to the RS485 port on the Device. Ensure the match of A and B interfaces.
2. Connect the video out cable of the PTZ camera to the video input port on the Device.
3. Turn on the PTZ camera.
Determine PTZ's Address, Baud, & Protocol
Method 1: Reboot and View OSD 1. Connect Analog or HD-CVI PTZ to Channel 1.
2. Bring up Channel 1 Live View
3. Power cycle PTZ.
4. Wait for PTZ to boot, and watch Channel 1 for PTZ Info.