Difference between revisions of "Thermal/Temperature Monitoring/3rd Party VMS/Milestone/Configure Milestone"
(→Alarm configuration) |
(→Add device in Milestone XProtect Management Client) |
||
Line 9: | Line 9: | ||
===Add device in Milestone XProtect Management Client=== | ===Add device in Milestone XProtect Management Client=== | ||
− | 1. Add Device to Recording Server | + | 1. Add Device to Recording Server by left clicking Recording Servers |
+ | |||
+ | Right click the server | ||
+ | |||
+ | Select '''Add Hardware''' | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_1.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_1.jpg|800px]] | ||
+ | |||
+ | 2. Select Manual Add | ||
+ | |||
+ | Click '''Next''' | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_2.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_2.jpg|800px]] | ||
+ | 3. Click Add | ||
+ | |||
+ | Enter the username and password for the camera | ||
+ | |||
+ | Click Next | ||
+ | |||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_3.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_3.jpg|800px]] | ||
+ | |||
+ | 4. Select ONVIF for device driver | ||
+ | |||
+ | Click Next | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_4.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_4.jpg|800px]] | ||
+ | |||
+ | 5. Enter the IP address of the camera | ||
+ | |||
+ | Select (Auto-detect) | ||
+ | |||
+ | Click Next | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_5.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_5.jpg|800px]] | ||
+ | |||
+ | The software will automatically detect the camera | ||
+ | |||
+ | Click Next | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_6.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_6.jpg|800px]] | ||
+ | |||
+ | Click Next | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_6-1.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_6-1.jpg|800px]] | ||
+ | |||
+ | 6. Check the box to enable all Hardware for the camera | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_7.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_7.jpg|800px]] | ||
+ | |||
+ | Click Next | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_7-1.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_7-1.jpg|800px]] | ||
+ | |||
+ | Click Finish | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_8.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_8.jpg|800px]] | ||
+ | |||
+ | The camera will appear in the list | ||
[[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_9.jpg|800px]] | [[File:Temperature_Monitoring_-_Milestone_-_Configure_Milestone_-_9.jpg|800px]] | ||
− | |||
===Add event in Milestone XProtect Management Client=== | ===Add event in Milestone XProtect Management Client=== |
Revision as of 17:10, 15 May 2020
Contents
Add Camera To Milestone and Configure Alarm Event
Description
This guide will show how to add the camera to the Milestone server and configure the alarm event for Temperature Monitoring
Prerequisites
- Milestone Corporate 2019 R3, device pack 10.8a
Step by Step Instructions
Add device in Milestone XProtect Management Client
1. Add Device to Recording Server by left clicking Recording Servers
Right click the server
Select Add Hardware
2. Select Manual Add
Click Next
3. Click Add
Enter the username and password for the camera
Click Next
4. Select ONVIF for device driver
Click Next
5. Enter the IP address of the camera
Select (Auto-detect)
Click Next
The software will automatically detect the camera
Click Next
Click Next
6. Check the box to enable all Hardware for the camera
Click Next
Click Finish
The camera will appear in the list