Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Cable Connections) |
|||
Line 10: | Line 10: | ||
|- | |- | ||
|Black | |Black | ||
+ | |RD– | ||
+ | |Negative electrode of external card reader. | ||
+ | |- | ||
|Red | |Red | ||
+ | |RD+ | ||
+ | |Positive electrode of external card reader. | ||
+ | |- | ||
|Blue | |Blue | ||
+ | |CASE | ||
+ | |Tamper alarm input of the external card reader. | ||
+ | |- | ||
|White | |White | ||
+ | |D1 | ||
+ | |Wiegand D1 input (connected to external card reader)/output (connected to controller). | ||
+ | |- | ||
|Green | |Green | ||
+ | |D0 | ||
+ | |Wiegand D0 input (connected to external card reader)/output (connected to controller). | ||
+ | |- | ||
|Brown | |Brown | ||
+ | |LED | ||
+ | |Connected to external reader indicator in | ||
+ | |- | ||
|Yellow | |Yellow | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|B | |B | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | |RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
*If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
*Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid. | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid. | ||
+ | |- | ||
+ | |Purple | ||
+ | |A | ||
|RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | |RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module). | ||
*If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | *If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power. | ||
*Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid | *Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | {| class="wikitable" | ||
+ | |||
+ | |- | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
|- | |- | ||
|rowspan="8"|CON2 | |rowspan="8"|CON2 |
Revision as of 17:08, 18 June 2020
Alarm Input and Output
Cable Connections
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON1 | |||
Black | RD– | Negative electrode of external card reader. | |
Red | RD+ | Positive electrode of external card reader. | |
Blue | CASE | Tamper alarm input of the external card reader. | |
White | D1 | Wiegand D1 input (connected to external card reader)/output (connected to controller). | |
Green | D0 | Wiegand D0 input (connected to external card reader)/output (connected to controller). | |
Brown | LED | Connected to external reader indicator in | |
Yellow | B | RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| |
Purple | A | RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
|