Notice: Firmware Links Under Maintenance We are currently undergoing maintenance on all firmware links. If any links are inaccessible, please email or contact Tech Support for the firmware. We appreciate your patience during the maintenance, thank you for your understanding.

Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"

Line 6: Line 6:
 
!|Cable Name
 
!|Cable Name
 
!|Description
 
!|Description
 +
|-
 +
|+CON1
 
|-
 
|-
 
|rowspan="9"|CON1
 
|rowspan="9"|CON1

Revision as of 17:09, 18 June 2020

Alarm Input and Output

Cable Connections

Port Cable Color Cable Name Description
CON1
CON1
Black RD– Negative electrode of external card reader.
Red RD+ Positive electrode of external card reader.
Blue CASE Tamper alarm input of the external card reader.
White D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown LED Connected to external reader indicator in
Yellow B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid



CON2
CON3