*Alarm1 = Normal | *Alarm1 = Normal |
Revision as of 17:26, 18 June 2020
Contents
Alarm Input and Output
Cable Connections
- Alarm1 = Normal
- Alarm2 = High Temp
- No alert for mask or face detection currently.
Contact 1
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON1 | |||
Black | RD– | Negative electrode of external card reader. | |
Red | RD+ | Positive electrode of external card reader. | |
Blue | CASE | Tamper alarm input of the external card reader. | |
White | D1 | Wiegand D1 input (connected to external card reader)/output (connected to controller). | |
Green | D0 | Wiegand D0 input (connected to external card reader)/output (connected to controller). | |
Brown | LED | Connected to external reader indicator in | |
Yellow | B | RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
| |
Purple | A | RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
|
Contact 2
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON2 | |||
White and red | ALARM1_NO | Alarm 1 normally open output port | |
White and orange | ALARM1_COM | Alarm 1 common output port. | |
White and blue | ALARM2_NO | Alarm 2 normally open output port. | |
White and gray | ALARM2_COM | Alarm 2 common output port. | |
White and green | GND | Connected to the common GND port. | |
White Brown | ALARM1 | Alarm 1 input port. | |
White and yellow | GND | Connected to the common GND port. | |
White and purple | ALARM2 | Alarm 2 input port. |
Contact 3
Port | Cable Color | Cable Name | Description |
---|---|---|---|
CON3 | |||
Black and red | RX | RS-232 receiving port. | |
Black and orange | TX | RS-232 sending port. | |
Black and blue | GND | Connected to the common GND port. | |
Black and gray | SR1 | Used for door contact detection. | |
Black and green | PUSH1 | Door open button of door No.1 | |
Black and brown | DOOR1_COM | Lock control common port. | |
Black and yellow | DOOR1_NO | Lock control normally open port. | |
Black and purple | DOOR1_NC | Lock control normally closed port. |