Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/Alarm Input and Output"
(→Door Strike Physical Setup) |
|||
Line 195: | Line 195: | ||
|- | |- | ||
|} | |} | ||
− | + | <embedvideo service="youtube">https://youtu.be/5toY3dhp2fI</embedvideo> | |
==High Body Temperature Indication Light== | ==High Body Temperature Indication Light== | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 217: | Line 217: | ||
|Alarm 2 common output port. | |Alarm 2 common output port. | ||
|} | |} | ||
− | + | <embedvideo service="youtube">https://youtu.be/5gC_ptUkYD8</embedvideo> | |
==Door Strike Physical Setup== | ==Door Strike Physical Setup== | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 239: | Line 239: | ||
|Lock control normally closed port. | |Lock control normally closed port. | ||
|} | |} | ||
− | + | <embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | |
==Door Release Button Physical Setup== | ==Door Release Button Physical Setup== | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 262: | Line 262: | ||
|- | |- | ||
|} | |} | ||
+ | <embedvideo service="youtube">https://youtu.be/dGHAkGemMjs</embedvideo> | ||
+ | ==WebUI Alarm Setup== | ||
+ | <embedvideo service="youtube">https://youtu.be/vjfoiNMyOB8</embedvideo> | ||
+ | ==SystemUI Set Temperature Threshold== | ||
+ | <embedvideo service="youtube">https://youtu.be/ZjVNCdwMB0I</embedvideo> |
Revision as of 15:45, 19 June 2020
Contents
Alarm Input and Output
Web Interface
Cable Connections
- Alarm1 = Normal
- Alarm2 = High Temp
- No alert for mask or face detection currently.
Contact 1
Contact 2
Contact 3
Normal Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and red | ALARM1_NO | Alarm 1 normally open output port | ||
White and orange | ALARM1_COM | Alarm 1 common output port. |
High Body Temperature Indication Light
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON2 | ||||
White and blue | ALARM2_NO | Alarm 2 normally open output port. | ||
White and gray | ALARM2_COM | Alarm 2 common output port. |
Door Strike Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and brown | DOOR1_COM | Lock control common port. | ||
Black and purple | DOOR1_NC | Lock control normally closed port. |
Door Release Button Physical Setup
Port | Cable Color | Cable Name | Description | |
---|---|---|---|---|
CON3 | ||||
Black and blue | GND | Connected to the common GND port. | ||
Black and green | PUSH1 | Door open button of door No.1 |