Alarm Input and Output

Cable Connections

Port Cable Color Cable Name Description
CON1
Black Red Blue White Green Brown Yellow Purple
RD– RD+ CASE D1 D0 LED B A
Negative electrode of external card reader. Positive electrode of external card reader. Tamper alarm input of the external card reader. Wiegand D1 input (connected to external card reader)/output (connected to controller). Wiegand D0 input (connected to external card reader)/output (connected to controller). Connected to external reader indicator in RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid
CON2
CON3