Alarm Input and Output
Cable Connections
- Alarm1 = Normal
- Alarm2 = High Temp
- No alert for mask or face detection currently.
File:Wire white green stripe.svg
Contact 1
| Port
|
Cable Color
|
Cable Name
|
Description
|
CON1
| CON1
|
Black
|
RD–
|
Negative electrode of external card reader.
|
| Red
|
RD+
|
Positive electrode of external card reader.
|
| Blue
|
CASE
|
Tamper alarm input of the external card reader.
|
| White
|
D1
|
Wiegand D1 input (connected to external card reader)/output (connected to controller).
|
| Green
|
D0
|
Wiegand D0 input (connected to external card reader)/output (connected to controller).
|
| Brown
|
LED
|
Connected to external reader indicator in
|
| Yellow
|
B
|
RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
- If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
- Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
|
| Purple
|
A
|
RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
- If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
- Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid
|
Contact 2
| Port
|
Cable Color
|
Cable Name
|
Description
|
CON2
| CON2
|
| White and red
|
ALARM1_NO
|
Alarm 1 normally open output port
|
| White and orange
|
ALARM1_COM
|
Alarm 1 common output port.
|
| White and blue
|
ALARM2_NO
|
Alarm 2 normally open output port.
|
| White and gray
|
ALARM2_COM
|
Alarm 2 common output port.
|
| White and green
|
GND
|
Connected to the common GND port.
|
| White Brown
|
ALARM1
|
Alarm 1 input port.
|
| White and yellow
|
GND
|
Connected to the common GND port.
|
| White and purple
|
ALARM2
|
Alarm 2 input port.
|
Contact 3
| Port
|
Cable Color
|
Cable Name
|
Description
|
CON3
| CON3
|
| Black and red
|
RX
|
RS-232 receiving port.
|
| Black and orange
|
TX
|
RS-232 sending port.
|
| Black and blue
|
GND
|
Connected to the common GND port.
|
| Black and gray
|
SR1
|
Used for door contact detection.
|
| Black and green
|
PUSH1
|
Door open button of door No.1
|
| Black and brown
|
DOOR1_COM
|
Lock control common port.
|
| Black and yellow
|
DOOR1_NO
|
Lock control normally open port.
|
| Black and purple
|
DOOR1_NC
|
Lock control normally closed port.
|