*Alarm1 = Normal
 +
*Alarm2 = High Temp
 +
*No alert for mask or face detection currently.
 
===Contact 1===
 
===Contact 1===
 
{| class="wikitable"
 
{| class="wikitable"

Revision as of 17:16, 18 June 2020

Alarm Input and Output

Cable Connections

  • Alarm1 = Normal
  • Alarm2 = High Temp
  • No alert for mask or face detection currently.

Contact 1

Port Cable Color Cable Name Description
CON1
CON1
Black RD– Negative electrode of external card reader.
Red RD+ Positive electrode of external card reader.
Blue CASE Tamper alarm input of the external card reader.
White D1 Wiegand D1 input (connected to external card reader)/output (connected to controller).
Green D0 Wiegand D0 input (connected to external card reader)/output (connected to controller).
Brown LED Connected to external reader indicator in
Yellow B RS-485 negative electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid.
Purple A RS-485 positive electrode input (connected to external card reader)/output (connected to controller, or connected to door control security module).
  • If the security module is enabled, you need to purchase access control security module separately. The security module needs separate power supply to provide power.
  • Once the security module is enabled, the exit button, lock control and firefighting linkage will be invalid

Contact 2

Port Cable Color Cable Name Description
CON2
CON2
White and red ALARM1_NO Alarm 1 normally open output port
White and orange ALARM1_COM Alarm 1 common output port.
White and blue ALARM2_NO Alarm 2 normally open output port.
White and gray ALARM2_COM Alarm 2 common output port.
White and green GND Connected to the common GND port.
White Brown ALARM1 Alarm 1 input port.
White and yellow GND Connected to the common GND port.
White and purple ALARM2 Alarm 2 input port.