Template:IVS Abandoned Missing Object SystemUI NewGUI

Description

This guide will show how to setup the Abandoned Object / Missing feature at the SystemUI with NewGUI

Abandoned object/missing function is used to detect if there are people, vehicle and objects abandoned or missing in some areas in the monitoring scene; it can trigger an alarm when the target object stays or is missing for a time which exceeds the desired time.

Prerequisites

  • Dahua device with Abandoned / Missing IVS feature

Video Instructions

Missing Object

Abandoned Object

Step By Step Instructions

Missing

1. From the Main Menu click AI

Missing - SystemUI - NewGUI - 0.jpg

2. Click Parameters

Missing - SystemUI - NewGUI - 1.jpg

3. Click Smart Plan

Missing - SystemUI - NewGUI - 2.jpg

4. Use the dropdown box to select the channel

Click the IVS icon (Lightbulb) to enable the Smart Plan

Missing - SystemUI - NewGUI - 3.jpg

5. Click Apply

Missing - SystemUI - NewGUI - 4.jpg

6. Click IVS

Missing - SystemUI - NewGUI - 5.jpg

7. Click Add to create a new IVS rule.

Missing - SystemUI - NewGUI - 6.jpg

8. Use the dropdown box to change rule Type to Missing

Missing - SystemUI - NewGUI - 7.jpg

Missing - SystemUI - NewGUI - 8.jpg

9. Click the Pencil icon under Draw to create the detection zone

Missing - SystemUI - NewGUI - 9.jpg

10. The video will fullscreen

Left click inside the window to begin drawing the detection zone

Missing - SystemUI - NewGUI - 10.jpg

11. Right click to finish drawing the zone

The Rule name will confirm the rule has been created

Click OK to save

Missing - SystemUI - NewGUI - 11.jpg

12. Click Apply to save all settings

Missing - SystemUI - NewGUI - 12.jpg

Abandoned

1. From the Main Menu click AI

Missing - SystemUI - NewGUI - 0.jpg

2. Click Parameters

Missing - SystemUI - NewGUI - 1.jpg

3. Click Smart Plan

Missing - SystemUI - NewGUI - 2.jpg

4. Use the dropdown box to select the channel

Click the IVS icon (Lightbulb) to enable the Smart Plan

Missing - SystemUI - NewGUI - 3.jpg

5. Click Apply

Missing - SystemUI - NewGUI - 4.jpg

6. Click IVS

Missing - SystemUI - NewGUI - 5.jpg

7. Use the dropdown box to change rule Type to Abandoned

Missing Object - SystemUI NewGUI - 1.jpg

8. Click the Pencil icon under Draw to create the detection zone

Missing Object - SystemUI NewGUI - 2.jpg

9. The video will fullscreen

Left click inside the window to begin drawing the detection zone

Missing Object - SystemUI NewGUI - 3.jpg

10. Right click to finish drawing the zone

The Rule name will confirm the rule has been created

Click OK to save

Missing Object - SystemUI NewGUI - 4.jpg

11. Click Apply to save all settings

Missing Object - SystemUI NewGUI - 5.jpg