Connection

IPCConnection.jpg

Parameter

Function

Max connection

It is the max Web connection for the same device. The value ranges from 1 to 20. Default connection amount is 10.

TCP port

Port range is 1025~65534. The default value is 37777. You can input the actual port number if necessary.

UDP port

Port range is 1025~65534. The default value is 37778. You can input the actual port number if necessary.

HTTP port

Port range is 1025~65524. The default value is 80. You can input the actual port number if necessary.

RTSP port

  • The default value is 554. Please leave blank if use default. User uses QuickTime or VLC can play the following formats. BlackBerry can play too.
  • Real-time monitoring URL format, please require real-time RTSP media server, require channel no., bit stream type in URL. You may need username and password.
  • User uses BlackBerry need to set encode mode to H.264B, resolution to CIF and turn off audio.

URL format is:

rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0

username/password/IP and port.

The IP is device IP and the port default value is 554. You can leave it in blank if it is the default value.

Follow standard RTP protocol and when encode mode is MJPEG, the max resolution only supports 2040*2040.

 HTTPs Enable

Check HTTPs enable, login as https://ip:port. Protect data. Default port is https://ip . It is disabled by default.

HTTPs Port

HTTPs communication port, range is 1025~65534, default is 443.

Note:

  • 0~1024, 37780~37880, 1900, 3800, 5000, 5050, 9999, 37776, 39999, 42323 are all special ports. User cannot modify them.
  • Avoid using default port value of other ports.

Onvif

ONVIF(Open Network Video Interface Forum),this standard describes network video mode, interface, data type and data interaction mode. ONVIF Standard’s aim is to achieve a network video frame agreement and makes the network video products (including video front-end, video equipment, etc.) from different manufacturers completely compatible.

ONVIF function default is closed. IPCONVIF.jpg