Difference between revisions of "Access Control/Products/ASI1212D"

 
(33 intermediate revisions by 7 users not shown)
Line 1: Line 1:
==ASI1212D==
+
=ASI1212D=
 +
__NOTOC__
 +
{| class="wikitable" style="width: 100%;"
 +
|+ASI1212D
 +
|-
 +
!|Specifications
 +
!|Manual
 +
!|Firmware
 +
|-
 +
|{{Template:DHI_ASI1212D_Specification_Template}}
 +
|<!--{{Template:ASC-Fingerprint-TA-Manual}}-->
 +
|{{Template:DH_ASI1212D}}
 +
|-
 +
|}
 
[[File:ASI1212D.png|right|400px]]
 
[[File:ASI1212D.png|right|400px]]
  
[[file:PDF_banner.jpg|float|link=File:ASI1212D-ASI1212D-D Users-Manual-V1 1 1-201805.pdf|600px]]
 
 
[[file:PDFDownloadBanner.jpg|float|link=File:ASI1212D-ASI1212D-D Users-Manual-V1 1 1-201805.pdf|600px]]
 
  
 +
[[File:ASI1212D_System_Structure.png|thumb|System Structure]]
 
===Notice===
 
===Notice===
 
Default IP address for this device is 192.168.1.108
 
Default IP address for this device is 192.168.1.108
 +
*To login as admin tap on '''OK''' and enter the 8-digit password
 +
{| class="wikitable"
 +
|+Local Interface Login
 +
|-
 +
!User name
 +
!Password
 +
|-
 +
|admin
 +
|88888888
 +
|}
 +
 +
{| class="wikitable"
 +
|-
 +
|+SmartPSS Login Info
 +
!Username
 +
!Password
 +
|-
 +
|admin
 +
|admin
 +
|}
  
User name: admin
+
'''Tapping the Bell icon twice changes between Letters, Numbers, and Symbols'''
  
Password: 888888888
+
<span style=color:red;font-style:italic;font-weight:bold>ASI1212D does support individual user pin, but this only works in SmartPSS. SmartPSS-AC and SmartPSS Lite do not work with this feature.</span>
  
===Firmware Download===
+
===ASI1212D Wiring Chart===
[http://dahuawiki.com/images/Firmware/DH_ASI1212D_Eng_V3.204.0000000.0.R.20180423.zip Click here to download]
 
  
===Features===
+
[[File:asa1212wiringout.jpg|400px]]
* Wiegand or RS-485 Interface to Reder
 
* TCP/IP to PC, Support for WAN Communication
 
* Touch Keyboard and LCD display
 
* Supports 30,000 Valid Cards and 150,000 Events
 
* Supports Card, Password, Fingerprint and a Combination of Credentials
 
* Add Devices in SmartPSS via P2P Connection
 
* Door Time Out, Intrusion, Duress and Tamper Alarms
 
* Anti-passback and Multi-card Open Options
 
* Supports 128 Efficient Time and Holiday Schedules
 
  
===Specifications===
+
[[File:asa1212wiringchart1.jpg|400px]]
  
{| class="wikitable" border="0" width="758" cellspacing="0" cellpadding="0"
+
[[File:asa1212wiringchart2.jpg|400px]]
|-
+
 
| class="xl66" width="417" height="19"|System
+
===Wiring Instructions===
| class="xl66" width="341"| 
+
 
|-
+
[[Access_Control/Products/ASI1212D/How_to_Add_DHI-ASI1212D_as_Reader_to_Access_Controller | How to Add DHI-ASI1212D as Reader to Access Controller]]
| class="xl66" width="417" height="19"|Main Processor
+
 
| class="xl66" width="341"|32-bit
+
[[Access_Control/Products/ASI1212D/How_to_Setup_Ring_Function_on_DHI-ASI1212D | How to Setup Ring Function on DHI-ASI1212D]]
|-
 
| class="xl66" width="417" height="19"|Flash Memory
 
| class="xl66" width="341"|32 MB
 
|-
 
| class="xl66" width="417" height="19"|Input/Output Ports
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Inputs
 
| class="xl66" width="341"|One (1) Door Sensor
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl65"|One (1) Exit Button
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl65"|One (1) Alarm
 
|-
 
| class="xl66" width="417" height="19"|Outputs
 
| class="xl65"|Three (3) Alarm Relays (Door Lock, Bell, Alarm)
 
|-
 
| class="xl66" width="417" height="19"|Card Reader
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Format
 
| class="xl65"|13.56 MHz MIFARE
 
|-
 
| class="xl66" width="417" height="19"|Range
 
| class="xl66" width="341"|3 cm to 8 cm (1.18 in. to 3.15 in.), maximum
 
|-
 
| class="xl66" width="417" height="19"|Response Time
 
| class="xl65"|< 0.1 s
 
|-
 
| class="xl66" width="417" height="19"|Fingerprint Reader
 
| class="xl67" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Response Time
 
| class="xl66" width="341"|≤ 0.5 s
 
|-
 
| class="xl66" width="417" height="19"|Recognition Time
 
| class="xl66" width="341"|≤ 1.5 s
 
|-
 
| class="xl66" width="417" height="19"|FAR
 
| class="xl66" width="341"|≤ 0.00004%
 
|-
 
| class="xl66" width="417" height="19"|FRR
 
| class="xl66" width="341"|≤ 0.15%
 
|-
 
| class="xl66" width="417" height="19"|Capacity
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Card Holders
 
| class="xl69"|30,000
 
|-
 
| class="xl66" width="417" height="19"|Events
 
| class="xl68" width="341"|150,000
 
|-
 
| class="xl66" width="417" height="19"|Fingerprints
 
| class="xl70" width="341"|3000
 
|-
 
| class="xl66" width="417" height="19"|Functions
 
| class="xl65"| 
 
|-
 
| class="xl66" width="417" height="19"|Network
 
| class="xl65"|P2P, DHCP
 
|-
 
| class="xl66" width="417" height="19"|Access Control
 
| class="xl66" width="341"|Anti Pass-back, Multi-interlock, Multi-card Unlock
 
|-
 
| class="xl66" width="417" height="19"|User Management
 
| class="xl66" width="341"|General, VIP, Guest, Patrol, Black List, Duress
 
|-
 
| class="xl66" width="417" height="19"|Alarm Functions
 
| class="xl66" width="341"|Door time-out, Intrusion, Duress,Tamper
 
|-
 
| class="xl66" width="417" height="19"|Schedule Settings
 
| class="xl65"|Schedule: 128 Groups
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|Period: 128 Groups
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|Holiday: 128 Groups
 
|-
 
| class="xl66" width="417" height="19"|RTC
 
| class="xl65"|Supported
 
|-
 
| class="xl66" width="417" height="19"|Voice Prompt
 
| class="xl66" width="341"|Supported
 
|-
 
| class="xl66" width="417" height="19"|Audible Indicator
 
| class="xl67" width="341"|Buzzer
 
|-
 
| class="xl66" width="417" height="19"|Interface
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|To PC
 
| class="xl65"|RJ45 (10/100 Mbps)
 
|-
 
| class="xl66" width="417" height="19"|To Reader
 
| class="xl65"|Wiegand 34/26, RS485
 
|-
 
| class="xl66" width="417" height="19"|Certifications
 
| class="xl65"| 
 
|-
 
| class="xl66" width="417" height="19"|Safety
 
| class="xl65"|EN 60950:2006+A2:2013
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|Conforms to UL Standards
 
|-
 
| class="xl66" width="417" height="19"|Electromagnetic Compatibility (EMC)
 
| class="xl66" width="341"|FCC CFR 47 Part 15 subpart B
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 55022:2010/AC:2011 (Class B)
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 55024:2010, EN 50130-4:2011,
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 61000-6-3:2007/A1:2011
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 61000-3-2:2006+A1:2009+A2:2009
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 61000-3-3:2013,
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-2:2008, IEC 61000-4-3:2006+A1:2007
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-4:2012, IEC 61000-4-5:2005,
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-6:2008, IEC 61000-4-8:2009
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-11:2004
 
|-
 
| class="xl66" width="417" height="19"|Electrical/Environmental
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Power Supply
 
| class="xl65"|9 to 15 VDC, 200 mA
 
|-
 
| class="xl66" width="417" height="19"|Operating Temperature
 
| class="xl66" width="341"|-5° C to +55° C (23° F to +131° F), 95% RH
 
|-
 
| class="xl66" width="417" height="19"|Ingress Protection
 
| class="xl66" width="341"|IP65
 
|-
 
| class="xl66" width="417" height="19"|Construction
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Dimensions
 
| class="xl65"|205.0 mm x 83.0 mm x 33.0 mm
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|(8.07 in. x 3.26 in. x 1.30 in.)
 
|-
 
| class="xl66" width="417" height="19"|Net Weight
 
| class="xl66" width="341"|0.44 kg (0.97 lb)
 
|-
 
| class="xl66" width="417" height="19"|Accessory - IC Card
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Model Number
 
| class="xl65"|MF11CS50
 
|-
 
| class="xl66" width="417" height="19"|Standard
 
| class="xl66" width="341"|MIFARE S50, 13.56 MHz
 
|-
 
| class="xl66" width="417" height="19"|Compatibility
 
| class="xl65"|ISO/IEC 14443A
 
|-
 
| class="xl66" width="417" height="19"|Range
 
| class="xl66" width="341"|Approximately 10 cm (3.94 in.)
 
|-
 
| class="xl66" width="417" height="19"|Dimensions
 
| class="xl66" width="341"|86.0 mm x 54.0 mm x 0.80 mm
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|(3.39 in. x 2.13 in. x 0.03 in.)
 
|-
 
| class="xl66" width="417" height="19"|Weight
 
| class="xl65"|0.006 kg (0.013 lb)
 
|-
 
| class="xl66" width="417" height="19"|Manufacturer/Brand
 
| class="xl66" width="341"|Dahua
 
|}
 
  
  

Latest revision as of 22:59, 10 August 2023

ASI1212D

ASI1212D
Specifications Manual Firmware

Build Date: 08-11-2021
ASI1212D.png


System Structure

Notice

Default IP address for this device is 192.168.1.108

  • To login as admin tap on OK and enter the 8-digit password
Local Interface Login
User name Password
admin 88888888
SmartPSS Login Info
Username Password
admin admin

Tapping the Bell icon twice changes between Letters, Numbers, and Symbols

ASI1212D does support individual user pin, but this only works in SmartPSS. SmartPSS-AC and SmartPSS Lite do not work with this feature.

ASI1212D Wiring Chart

Asa1212wiringout.jpg

Asa1212wiringchart1.jpg

Asa1212wiringchart2.jpg

Wiring Instructions

How to Add DHI-ASI1212D as Reader to Access Controller

How to Setup Ring Function on DHI-ASI1212D