Difference between revisions of "Template:Kiosk WebUI Alarm Linkage"
(10 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
</span><span class="left"></span></div> | </span><span class="left"></span></div> | ||
<div class="mw-collapsible-content"> | <div class="mw-collapsible-content"> | ||
− | + | {| class="wikitable" | |
− | + | !|Name | |
− | [[file:Kiosk_Alarm_Linkage_Page.png| | + | !|Description |
− | + | |- | |
− | [[file:Kiosk_Alarm_Log_Page.png| | + | !|Alarm Input |
+ | |You cannot modify the value. Keep it default. | ||
+ | |- | ||
+ | !|Name | ||
+ | |Enter a zone name. | ||
+ | |- | ||
+ | !|Alarm Input Type | ||
+ | | | ||
+ | There are two options: NO and NC. | ||
+ | If alarm input type of the alarm device you purchased is NO, then you | ||
+ | should select NO; otherwise you should select NC. | ||
+ | |- | ||
+ | !|Fire Link Enable | ||
+ | | | ||
+ | If fire link is enabled the access controller will output alarms when fire | ||
+ | alarms are triggered. The alarm details will be displayed in the alarm | ||
+ | log.<br /> | ||
+ | Alarm output and access link are NO by default if fire link is enabled. | ||
+ | |- | ||
+ | !|Alarm Output Enable | ||
+ | | | ||
+ | The relay can output alarm information (will be sent to the management | ||
+ | platform) if the Alarm Output is enabled. | ||
+ | |- | ||
+ | !|Duration (Sec.) | ||
+ | |The alarm duration, and the range is 1–300 seconds. | ||
+ | |- | ||
+ | !|Alarm Output Channel | ||
+ | | | ||
+ | You can select an alarm output channel according to the alarming | ||
+ | device that you have installed. Each alarm device can be regarded as | ||
+ | a channel. | ||
+ | |- | ||
+ | !|Access Link Enable | ||
+ | | | ||
+ | After the Access Link is enabled, the access controller will be normally | ||
+ | on or normally closed when there are input alarm signals. | ||
+ | |- | ||
+ | !|Channel Type | ||
+ | |There are two options: NO and NC. | ||
+ | |- | ||
+ | |} | ||
+ | ==<span style="color: white;">Alarm Linkage</span>== | ||
+ | [[file:Kiosk_Alarm_Linkage_Page.png|800px]] | ||
+ | ==<span style="color: white;">Alarm Log</span>== | ||
+ | [[file:Kiosk_Alarm_Log_Page.png|800px]] | ||
</div></div> | </div></div> |
Latest revision as of 15:47, 23 June 2020
Name | Description |
---|---|
Alarm Input | You cannot modify the value. Keep it default. |
Name | Enter a zone name. |
Alarm Input Type |
There are two options: NO and NC. If alarm input type of the alarm device you purchased is NO, then you should select NO; otherwise you should select NC. |
Fire Link Enable |
If fire link is enabled the access controller will output alarms when fire
alarms are triggered. The alarm details will be displayed in the alarm
log. |
Alarm Output Enable |
The relay can output alarm information (will be sent to the management platform) if the Alarm Output is enabled. |
Duration (Sec.) | The alarm duration, and the range is 1–300 seconds. |
Alarm Output Channel |
You can select an alarm output channel according to the alarming device that you have installed. Each alarm device can be regarded as a channel. |
Access Link Enable |
After the Access Link is enabled, the access controller will be normally on or normally closed when there are input alarm signals. |
Channel Type | There are two options: NO and NC. |