Difference between revisions of "Thermal/DHI-ASI7213X-T1/Instructions/SystemUI Breakdown"
(→Main Menu) |
(→Face Parameter) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 14: | Line 14: | ||
==USB Export== | ==USB Export== | ||
[[file:Kiosk_SystemUI_USB_Export.png|400px]] | [[file:Kiosk_SystemUI_USB_Export.png|400px]] | ||
+ | |||
+ | {| class="wikitable" | ||
+ | !|Name | ||
+ | !|File Name | ||
+ | !|Description | ||
+ | |- | ||
+ | !|User | ||
+ | |User_Info.bak | ||
+ | |Backup and transfer User Settings from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 | ||
+ | |- | ||
+ | !|Face Feature Value | ||
+ | |Face_Info.bak | ||
+ | |Backup and transfer Face Feature Value from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 | ||
+ | |- | ||
+ | !|Card | ||
+ | |CardNo_Info.bak | ||
+ | |Backup and transfer Card Info from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 | ||
+ | |- | ||
+ | !|FP | ||
+ | | | ||
+ | |Backup and transfer FP Data from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 | ||
+ | |- | ||
+ | !|Record | ||
+ | |Card_Punch_Records_0.xml | ||
+ | |Backup records in XML format for viewing on a PC | ||
+ | |- | ||
+ | |} | ||
+ | |||
==USB Import== | ==USB Import== | ||
[[file:Kiosk_SystemUI_USB_Import.png|400px]] | [[file:Kiosk_SystemUI_USB_Import.png|400px]] | ||
==Face Parameter== | ==Face Parameter== | ||
[[file:Kiosk_SystemUI_Face_Parameter.png|400px]] | [[file:Kiosk_SystemUI_Face_Parameter.png|400px]] | ||
+ | |||
+ | |||
+ | Temp Rect: Set whether to enable the temperature monitoring | ||
+ | box or not. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | !|Name | ||
+ | !|Description | ||
+ | |- | ||
+ | !|Face Recognition Threshold | ||
+ | |Face recognition accuracy can be adjusted. The larger the value is, the higher the accuracy will be. | ||
+ | |- | ||
+ | !|Max. Angle of Face Recognition | ||
+ | |Set the control panel shooting angle of profiles. The larger the value is, the wider range of the profiles will be recognized. | ||
+ | |- | ||
+ | !|Pupillary Distance | ||
+ | |Pupillary distance is the pixel value of the image between the centers of the pupils in each eye. You need to set an appropriate value so that the access controller can recognize faces as needed. The value changes according to the face sizes and the distance between faces and the lens. The closer the face is to the lens, the greater the value should be. If an adult is 1.5 meters away from the lens, the pupillary distance value can be within 50 to 70. | ||
+ | |- | ||
+ | !|Recognition Timeout | ||
+ | |When a person who does not have the access permission stands in front of the access controller and gets the face recognized, the controller will prompt that face recognition failed. The prompt interval is called recognition timeout. | ||
+ | |- | ||
+ | !|Recognition Interval | ||
+ | |When a person who has the access permission stands in front of the access controller and gets the face recognized, the controller will prompt that face recognition succeeded. The prompt interval is the recognition interval. | ||
+ | |- | ||
+ | !|Invalid Face Prompt Interval | ||
+ | |When a face has no access permission stands in front of the access controller, the controller will prompt that the face is invalid. The prompt interval is invalid face prompt interval. | ||
+ | |- | ||
+ | !|Anti-fake Threshold | ||
+ | |This function prevents people from unlocking by human face images or face models. The larger the value is, the more difficult face images can unlock the door. The recommended value range is above 80. | ||
+ | |- | ||
+ | !|Temperature Monitoring | ||
+ | | | ||
+ | Set whether to enable the body temperature monitoring. | ||
+ | *Temp Unit: Select a temperature unit. | ||
+ | *Temp Rect: Set whether to enable the temperature monitoring box or not. | ||
+ | *Temp Monitoring Distance (cm): The value is 0 by default. Set other values to enable temperature monitoring within a defined distance. 80 cm is recommended. | ||
+ | *Temp Threshold (°C): Set the temperature threshold. The monitored body temperature will be judged as high temperature if it is greater than or equal to the set value. | ||
+ | *Temp Correction Value: This parameter is for testing. The difference of the temperature monitoring environment might cause the temperature deviation between the monitored temperature and the actual temperature. You can select multiple monitored samples for testing, and then correct the temperature deviation by this parameter according to the comparison between the monitored temperature and the actual temperature. For example, if the monitored temperature is 0.5°C lower than the actual temperature, the correction value is set to 0.5°C; if the monitored temperature is 0.5°C higher than the actual temperature, the correction value is set to -0.5°C. | ||
+ | |- | ||
+ | !|Mask Mode | ||
+ | | | ||
+ | *No detect: Mask is not detected during face recognition. | ||
+ | *Mask reminder: Mask is detected during face recognition. If the person is detected without wearing a mask, the system will prompt mask reminder and passage is allowed. | ||
+ | *Mask intercept: Mask is detected during face recognition. If the person is detected without wearing a mask, the system will prompt mask reminder and passage is not allowed | ||
+ | |- | ||
+ | |} |
Latest revision as of 16:58, 23 June 2020
Contents
DHI-ASI7213X-T1: SystemUI
Main Screen
Unlock Mode
Main Menu
New User
USB Export
Name | File Name | Description |
---|---|---|
User | User_Info.bak | Backup and transfer User Settings from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 |
Face Feature Value | Face_Info.bak | Backup and transfer Face Feature Value from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 |
Card | CardNo_Info.bak | Backup and transfer Card Info from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 |
FP | Backup and transfer FP Data from one DHI-ASI7213X-T1 to another DHI-ASI7213X-T1 | |
Record | Card_Punch_Records_0.xml | Backup records in XML format for viewing on a PC |
USB Import
Face Parameter
Temp Rect: Set whether to enable the temperature monitoring
box or not.
Name | Description |
---|---|
Face Recognition Threshold | Face recognition accuracy can be adjusted. The larger the value is, the higher the accuracy will be. |
Max. Angle of Face Recognition | Set the control panel shooting angle of profiles. The larger the value is, the wider range of the profiles will be recognized. |
Pupillary Distance | Pupillary distance is the pixel value of the image between the centers of the pupils in each eye. You need to set an appropriate value so that the access controller can recognize faces as needed. The value changes according to the face sizes and the distance between faces and the lens. The closer the face is to the lens, the greater the value should be. If an adult is 1.5 meters away from the lens, the pupillary distance value can be within 50 to 70. |
Recognition Timeout | When a person who does not have the access permission stands in front of the access controller and gets the face recognized, the controller will prompt that face recognition failed. The prompt interval is called recognition timeout. |
Recognition Interval | When a person who has the access permission stands in front of the access controller and gets the face recognized, the controller will prompt that face recognition succeeded. The prompt interval is the recognition interval. |
Invalid Face Prompt Interval | When a face has no access permission stands in front of the access controller, the controller will prompt that the face is invalid. The prompt interval is invalid face prompt interval. |
Anti-fake Threshold | This function prevents people from unlocking by human face images or face models. The larger the value is, the more difficult face images can unlock the door. The recommended value range is above 80. |
Temperature Monitoring |
Set whether to enable the body temperature monitoring.
|
Mask Mode |
|