Difference between revisions of "Access Control/Products/ASI1212D"

Line 34: Line 34:
  
 
Password: admin
 
Password: admin
 
===Firmware Download===
 
[https://dahuawiki.com/images/Firmware/Attendance/DH_ASI1212D_Eng_V3.204.0000000.0.R.20180423.zip Click here to download]
 
  
 
===Features===
 
===Features===
Line 85: Line 82:
  
 
===Specifications===
 
===Specifications===
 
+
{{#iDisplay:https://dahuawiki.com/index.php?action=ajax&title=-&rs=SecureFileStore::getFile&f=/d/dd/Datasheet_Access_FingerprintController_DHI_ASI1212D_v001_008.pdf|100%|600}}
{| class="wikitable" border="0" width="758" cellspacing="0" cellpadding="0"
 
|-
 
| class="xl66" width="417" height="19"|System
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Main Processor
 
| class="xl66" width="341"|32-bit
 
|-
 
| class="xl66" width="417" height="19"|Flash Memory
 
| class="xl66" width="341"|32 MB
 
|-
 
| class="xl66" width="417" height="19"|Input/Output Ports
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Inputs
 
| class="xl66" width="341"|One (1) Door Sensor
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl65"|One (1) Exit Button
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl65"|One (1) Alarm
 
|-
 
| class="xl66" width="417" height="19"|Outputs
 
| class="xl65"|Three (3) Alarm Relays (Door Lock, Bell, Alarm)
 
|-
 
| class="xl66" width="417" height="19"|Card Reader
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Format
 
| class="xl65"|13.56 MHz MIFARE
 
|-
 
| class="xl66" width="417" height="19"|Range
 
| class="xl66" width="341"|3 cm to 8 cm (1.18 in. to 3.15 in.), maximum
 
|-
 
| class="xl66" width="417" height="19"|Response Time
 
| class="xl65"|< 0.1 s
 
|-
 
| class="xl66" width="417" height="19"|Fingerprint Reader
 
| class="xl67" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Response Time
 
| class="xl66" width="341"|≤ 0.5 s
 
|-
 
| class="xl66" width="417" height="19"|Recognition Time
 
| class="xl66" width="341"|≤ 1.5 s
 
|-
 
| class="xl66" width="417" height="19"|FAR
 
| class="xl66" width="341"|≤ 0.00004%
 
|-
 
| class="xl66" width="417" height="19"|FRR
 
| class="xl66" width="341"|≤ 0.15%
 
|-
 
| class="xl66" width="417" height="19"|Capacity
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Card Holders
 
| class="xl69"|30,000
 
|-
 
| class="xl66" width="417" height="19"|Events
 
| class="xl68" width="341"|150,000
 
|-
 
| class="xl66" width="417" height="19"|Fingerprints
 
| class="xl70" width="341"|3000
 
|-
 
| class="xl66" width="417" height="19"|Functions
 
| class="xl65"| 
 
|-
 
| class="xl66" width="417" height="19"|Network
 
| class="xl65"|P2P, DHCP
 
|-
 
| class="xl66" width="417" height="19"|Access Control
 
| class="xl66" width="341"|Anti Pass-back, Multi-interlock, Multi-card Unlock
 
|-
 
| class="xl66" width="417" height="19"|User Management
 
| class="xl66" width="341"|General, VIP, Guest, Patrol, Black List, Duress
 
|-
 
| class="xl66" width="417" height="19"|Alarm Functions
 
| class="xl66" width="341"|Door time-out, Intrusion, Duress,Tamper
 
|-
 
| class="xl66" width="417" height="19"|Schedule Settings
 
| class="xl65"|Schedule: 128 Groups
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|Period: 128 Groups
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|Holiday: 128 Groups
 
|-
 
| class="xl66" width="417" height="19"|RTC
 
| class="xl65"|Supported
 
|-
 
| class="xl66" width="417" height="19"|Voice Prompt
 
| class="xl66" width="341"|Supported
 
|-
 
| class="xl66" width="417" height="19"|Audible Indicator
 
| class="xl67" width="341"|Buzzer
 
|-
 
| class="xl66" width="417" height="19"|Interface
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|To PC
 
| class="xl65"|RJ45 (10/100 Mbps)
 
|-
 
| class="xl66" width="417" height="19"|To Reader
 
| class="xl65"|Wiegand 34/26, RS485
 
|-
 
| class="xl66" width="417" height="19"|Certifications
 
| class="xl65"| 
 
|-
 
| class="xl66" width="417" height="19"|Safety
 
| class="xl65"|EN 60950:2006+A2:2013
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|Conforms to UL Standards
 
|-
 
| class="xl66" width="417" height="19"|Electromagnetic Compatibility (EMC)
 
| class="xl66" width="341"|FCC CFR 47 Part 15 subpart B
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 55022:2010/AC:2011 (Class B)
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 55024:2010, EN 50130-4:2011,
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 61000-6-3:2007/A1:2011
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 61000-3-2:2006+A1:2009+A2:2009
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|EN 61000-3-3:2013,
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-2:2008, IEC 61000-4-3:2006+A1:2007
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-4:2012, IEC 61000-4-5:2005,
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-6:2008, IEC 61000-4-8:2009
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|IEC 61000-4-11:2004
 
|-
 
| class="xl66" width="417" height="19"|Electrical/Environmental
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Power Supply
 
| class="xl65"|9 to 15 VDC, 200 mA
 
|-
 
| class="xl66" width="417" height="19"|Operating Temperature
 
| class="xl66" width="341"|-5° C to +55° C (23° F to +131° F), 95% RH
 
|-
 
| class="xl66" width="417" height="19"|Ingress Protection
 
| class="xl66" width="341"|IP65
 
|-
 
| class="xl66" width="417" height="19"|Construction
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Dimensions
 
| class="xl65"|205.0 mm x 83.0 mm x 33.0 mm
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|(8.07 in. x 3.26 in. x 1.30 in.)
 
|-
 
| class="xl66" width="417" height="19"|Net Weight
 
| class="xl66" width="341"|0.44 kg (0.97 lb)
 
|-
 
| class="xl66" width="417" height="19"|Accessory - IC Card
 
| class="xl66" width="341"| 
 
|-
 
| class="xl66" width="417" height="19"|Model Number
 
| class="xl65"|MF11CS50
 
|-
 
| class="xl66" width="417" height="19"|Standard
 
| class="xl66" width="341"|MIFARE S50, 13.56 MHz
 
|-
 
| class="xl66" width="417" height="19"|Compatibility
 
| class="xl65"|ISO/IEC 14443A
 
|-
 
| class="xl66" width="417" height="19"|Range
 
| class="xl66" width="341"|Approximately 10 cm (3.94 in.)
 
|-
 
| class="xl66" width="417" height="19"|Dimensions
 
| class="xl66" width="341"|86.0 mm x 54.0 mm x 0.80 mm
 
|-
 
| class="xl66" width="417" height="19"| 
 
| class="xl66" width="341"|(3.39 in. x 2.13 in. x 0.03 in.)
 
|-
 
| class="xl66" width="417" height="19"|Weight
 
| class="xl65"|0.006 kg (0.013 lb)
 
|-
 
| class="xl66" width="417" height="19"|Manufacturer/Brand
 
| class="xl66" width="341"|Dahua
 
|}
 
 
 
 
 
  
  

Revision as of 22:49, 4 March 2020

ASI1212D

ASI1212D
Specifications Quick Start Guide Manual Firmware
Coming Soon

Build Date: 08-11-2021
ASI1212D.png

float

float

System Structure

Notice

Default IP address for this device is 192.168.1.108

User name: admin

Password: 888888888

or

User name: admin

Password: admin

Features

  • Wiegand or RS-485 Interface to Reder
  • TCP/IP to PC, Support for WAN Communication
  • Touch Keyboard and LCD display
  • Supports 30,000 Valid Cards and 150,000 Events
  • Supports Card, Password, Fingerprint and a Combination of Credentials
  • Add Devices in SmartPSS via P2P Connection
  • Door Time Out, Intrusion, Duress and Tamper Alarms
  • Anti-passback and Multi-card Open Options
  • Supports 128 Efficient Time and Holiday Schedules

ASI1212D Wiring Chart

Asa1212wiringout.jpg

Asa1212wiringchart1.jpg

Asa1212wiringchart2.jpg

Wiring Guide

This guide demonstrates wiring the 'Ring' function. A light is in place to show when the relay has been successfully triggered

Please reference the device Wiring Guide for the correct relay connections for your purposes

1. Check the wiring diagram to confirm what connections need to be made

For Ring function:

ASI1212DRing.jpg

The Red and Black wires labeled CON3 are used

2. Wire the connections in line with the desired devices (and power if required) to complete a circuit.

In this example a light (and external power) is being used to show when the relay has been successfully triggered.

ASI1212D Wiring.jpg

3. After wiring the circuit press the Ring button and the relay should engage

In this example, the light will turn on

ASI1212D Wiring 2.jpg


Specifications