Difference between revisions of "Thermal/Configure Temperature Global Setup"
(Created page with "=Configure Temperature Global Setup= ==Description== Temperature Global Setup File:thermal_spot_torch.gif ==Prerequisites== * Dahua device with Temperature function -...") |
(→Step by Step Instructions) |
||
| Line 19: | Line 19: | ||
Click Login | Click Login | ||
| + | |||
| + | |||
| + | |||
| + | |||
| + | {| class="wikitable" | ||
| + | ! style="font-weight:bold; font-size:15px; font-family:Arial, Helvetica, sans-serif !important;; background-color:#c0c0c0; color:#000000;" | Parameter | ||
| + | ! style="font-weight:bold; font-size:15px; font-family:Arial, Helvetica, sans-serif !important;; background-color:#c0c0c0; color:#000000;" | Description | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Temperature Switch | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Select the check box to enable this function | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Temperature Unit | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Choose from Celsius (°C) and Fahrenheit (°F) | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Relative Humidity | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Relative humidity of environment. Ranges from 0RH - 100%RH | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Atmospheric Temperature | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Temperature of the environment. Ranges from -50 °C to 327.7 °C | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Target Radiation Coefficient | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Set Radiation coefficient of targets that are shot by this Device. | ||
| + | Ranges from 0.5 - 1. | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Target Distance | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Distance from the camera to targets that are shot. | ||
| + | Ranges from 0m - 10000m | ||
| + | |- | ||
| + | | style="font-size:small; font-family:Arial, Helvetica, sans-serif !important;;" | Target Reflection Temperature | ||
| + | | style="font-size:x-small; font-family:Arial, Helvetica, sans-serif !important;;" | Temperature of targets that are shot by this Device. Ranges from -50 °C to 327.7 °C | ||
| + | |} | ||
Revision as of 21:58, 14 April 2020
Contents
Configure Temperature Global Setup
Description
Temperature Global Setup
Prerequisites
- Dahua device with Temperature function - DH-TPC-BF5400 used for guide
Video Instructions
Step by Step Instructions
1. Enter the IP of the device into a browser (default 192.168.1.108)
At the Web Login
Enter the Username and Password
Click Login
| Parameter | Description |
|---|---|
| Temperature Switch | Select the check box to enable this function |
| Temperature Unit | Choose from Celsius (°C) and Fahrenheit (°F) |
| Relative Humidity | Relative humidity of environment. Ranges from 0RH - 100%RH |
| Atmospheric Temperature | Temperature of the environment. Ranges from -50 °C to 327.7 °C |
| Target Radiation Coefficient | Set Radiation coefficient of targets that are shot by this Device.
Ranges from 0.5 - 1. |
| Target Distance | Distance from the camera to targets that are shot.
Ranges from 0m - 10000m |
| Target Reflection Temperature | Temperature of targets that are shot by this Device. Ranges from -50 °C to 327.7 °C |