Use Body Temp Monitoring with TPC-BF5421-T and DSS-Express
Description
These instructions will show how to use Body Temperature Monitoring on DSS Express to view Temperature Monitoring events from the TPC-BF5421-T
Prerequisites
- Completed Add TPC-BF5421-T to DSS-Express
Video Instructions
Step by Step Instructions
Review Configuration
These first instructions are covered in the previous set of instructions - Add TPC-BF5421-T to DSS-Express.
It is important to review that the settings are correct for Storage/Device at DSS Express for the Body Temperature Measurement to work
Review Configuration - Click to expand
Enter the username/password
Click Login
Confirm Storage is configured properly: Go to Config from the Main Menu, select Storage
The partitions should appear on the local drive as pictured:
Confirm device (camera) is configured properly:
Go to Device from the Main Menu
Click the edit (pencil) icon next to the device in the list
Confirm the following are selected under both channels of the camera under Features:
- IVS Alarm
- IR Temperature Measurement
- Access Snapshot
Use Body Temperature Monitoring
1. From the Homepage of DSS Express
Click Body Temperature Monitoring
2. Click the device icon to select a device to use
3. Select the TPC-BF5421-T in the list as shown
Click OK
Generated Temperature Events from the camera will appear in the interface: