Revision as of 15:15, 27 May 2022
Temperature Measurement
Solution Specifications | Camera Specifications | NVR Specifications |
---|---|---|
Template:DH-TPC-BF5421-T Specification Template | Template:DHI-NVR5216-16P-I Specification Template |
Description
The Dahua Temperature Monitoring solution offers the latest hybrid thermal network camera that combines a Vanadium Oxide (VOx) sensor with a 2 MP visible-light sensor. The solution also provides a blackbody calibration device that maintains a constant temperature as a reference point for the thermal camera. The thermal camera coupled with the blackbody calibration device and a feature-rich 4 TB Network Video Recorder delivers a contactless solution for continuous, contactless, and non-invasive temperature monitoring.
The Dahua Thermal Temperature Monitoring Solution is not a medical device and is not designed or intended for diagnosis, prevention, or treatment of any disease or condition. The solution is a screening tool that businesses and households can use to identify individuals with elevated skin temperature compared to a customizable reference temperature on or entering their premises.
Video Example
Coming Soon
Solution Features
- Safe, Effective, and Accurate Temperature Measurement
- ±0.3° C Temperature Measurement (with blackbody)
- Contactless and Fast Multi-person Screening
- Recommended for Use in Commercial Buildings, Healthcare Facilities, Airports, Metro Stations, and Public Gathering Locations
Required Devices
- DH-TPC-BF3221-T or DH-TPC-BF5421-T Thermal Hybrid Network Camera
- DHI-NVR5216-16P-I 16 Channel NVR
- JQ-D70Z Blackbody
Recommended Accesories
- VCT-999 Tripod (x2)
- RQW026-00 Connector (x2)
A set of temperature measuring equipment requires two tripods and two transfer parts, one for the camera and one for the Blackbody device
Installation Requirements
Distance between camera and blackbody | Distance between the human forehead and the camera | Channel Width |
9.8 ft (3m) | 9.8 ft (3m) | 4.3 ft (1.3m) |
Specifications