NVR FAQ
|
Problem
|
Solution
|
NVR will not boot.
|
Input power is not correct.
|
Power connection is not correct.
|
Power switch button is damaged.
|
Program upgrade is wrong.
|
HDD malfunction or something wrong with HDD ribbon.
|
Seagate DB35.1, DB35.2,SV35 or Maxtor 17-g has compatibility problem. Please upgrade to the latest version to solve this problem.
|
Front panel error.
|
Main board is damaged.
|
NVR often automatically shuts down or stops running.
|
Input voltage is not stable or it is too low.
|
HDD malfunction or something wrong wit the ribbon.
|
Button power is not enough.
|
Front video signal is not stable.
|
Working environment is too harsh, too much dust.
|
Hardware malfunction.
|
System is unable to detect hard drive.
|
HDD is broken.
|
HDD ribbon is damaged.
|
HDD cable connection is loose.
|
Main board SATA port is broken.
|
Video loss from 1, multiple, or all channels.
|
Program is not compatible. Please upgrade to the latest version.
|
Brightness is 0. Please restore factory default setup.
|
Check your screen saver.
|
NVR hardware malfunctions.
|
I can not search local records.
|
HDD ribbon is damaged.
|
HDD is broken.
|
Upgraded program is not compatible.
|
The recorded file has been overwritten.
|
Record function has been disabled
|
Video is distorted when searching local records.
|
Video quality setup is too low.
|
Program read error, bit data is too small. There is mosaic in the full screen. Please restart the NVR to solve this problem.
|
HDD data ribbon error.
|
HDD malfunction.
|
NVR hardware malfunctions.
|
Time display is not correct.
|
Setup is not correct
|
Battery contact is not correct or voltage is too low.
|
Crystal is broken.
|
NVR can not control PTZ
|
Front panel PTZ error
|
PTZ decoder setup, connection or installation is not correct.
|
Cable connection is not correct.
|
PTZ setup is not correct.
|
PTZ decoder and NVR protocol is not compatible.
|
PTZ decoder and NVR address is not compatible.
|
When there are several decoders, please add 120 Ohm between the PTZ decoder A/B cables furthest end to delete the reverberation or impedance matching. Otherwise the PTZ control is not stable.
|
The distance is too far.
|
Unable to login to WebGUI
|
For Windows 98 or Windows ME user, please update your system to Windows 2000 sp4. Or you can install client-end software of lower version. Please note right now, our NVR is not compatible with Windows VISTA control.
|
ActiveX control has been disabled.
|
No dx8.1 or higher. Please upgrade display card driver.
|
Network connection error.
|
Network setup error.
|
Password or user name is invalid.
|
Client-end is not compatible with NVR program.
|
There is only mosaic no video when preview or playback video file remotely.
|
Network fluency is not good.
|
Client-end resources are limit.
|
Current user has no right to monitor.
|
Network connection is not stable.
|
IP address conflict.
|
MAC address conflict.
|
PC or device network card is not good.
|
Keyboard can not control NVR.
|
NVR serial port setup is not correct
|
Address is not correct
|
When there are several switchers, power supply is not enough.
|
Transmission distance is too far.
|
Alarm signal can not been disarmed.
|
Alarm setup is not correct.
|
Alarm output has been open manually.
|
Input device error or connection is not correct.
|
Some program versions may have this problem. Please upgrade your system.
|
Alarm function is null.
|
Alarm setup is not correct.
|
Alarm cable connection is not correct.
|
Alarm input signal is not correct.
|
There are two loops connect to one alarm device.
|
Record storage period is not enough.
|
Camera quality is too low. Lens is dirty. Camera is installed against the light. Camera aperture setup is not correct.
|
HDD capacity is not enough.
|
HDD is damaged.
|
Can not playback the downloaded file.
|
There is no media player.
|
No DXB8.1 or higher graphic acceleration software.
|
There is no DivX503Bundle.exe control when you play the file transformed to AVI via media player.
|
No DivX503Bundle.exe or ffdshow-2004 1012 .exe in Windows XP OS.
|
Forgot local menu operation password or network password
|
Please contact your local service engineer or our sales person for help. We can guide you to solve this problem.
|
There is no video. The screen is in black.
|
IPC IP address is not right.
|
IPC port number is not right.
|
IPC account (user name/password) is not right.
|
IPC is offline.
|
The displayed video is not full in the monitor.
|
Please cheek current resolution setup. If the current setup is 1920*1080, then you need to set the monitor resolution as 1920*1080
|
There is no HDMI output.
|
Displayer is not in HDMI mode.
|
HDMI cable connection is not right.
|
The video is not fluent when I view in multiple-channel mode from the client-end.
|
The network bandwidth is not sufficient. The multiple-channel monitor operation needs at least 100M or higher.
|
Your PC resources are not sufficient. For 16-ch remote monitor operation, the PC shall have the following environment: Quad Core, 2G or higher memory, independent displayer, display card memory 256M or higher.
|
I can not connect to the IPC
|
Please make sure the IPC has booted up.
|
IPC network connection is right and it is online
|
IPC IP is in the blacklist.
|
The device has connected to the too many IPC. It can not transmit the video.
|
Check the IPC port value and the time zone is the same as the NVR.
|
Make sure current network environment is stable.
|
After I set the NVR resolution as 1080P, my monitor can not display.
|
Shut down the device and then reboot. When you reboot, please press the Fn button at the same time and then release after 5 seconds. You can restore NVR resolution to the default setup.
|
After I login the Web, I can not find the remote interface to add the IPC.
|
Please clear the Web controls and load again.
|
I use the VGA montior. If I use the multple-window mode, I see the video from the main stream or the sub stream.
|
For 32-channel series product, the 9/16-window is using the sub stream.
|
For 4/8/16 series product, system is using the main stream no matter you are in what display mode.
|
IP Camera FAQ
|
Problem
|
Solution
|
My IP Camera is off line from time to time
|
Check if the network environment is good and the network cable hole plug of IPC end is loose.
|
Check if there is IP conflict.
|
Check if the device is under normal power supply.
|
Check if the device upgraded to a wrong program.
|
My IP Camera is off line from time to time
|
Log in again to check if upgrade is successful, because sometimes the progress bar doesn’t show feedback in time due to the network environment.
|
Check if the network environment is normal, and there is disconnection or power failure during upgrade.
|
Check if the program and the device are matched.
|
I can use “Ping” to test that the IPC is on line after upgrade, but fail to log in.
|
Check if the WEB port was modified.
|
Reset the device and log in again.
|
There is no code stream when I log in and the network program restarts constantly after upgrade.
|
Check if there is IP conflict or network disconnection.
|
Check if the device is under normal power supply.
|
Check if each connection line is loose inside the device after disassembling the camera.
|
Check if the application program of IPC is corresponding to the model, and check if N/P format program is correct.
|
Check if the control and WEB are correct, there is control running permission under WIN7, you can delete the control under C:\Program Files\webrec and eliminate IE buffer memory to reload control and WEB. Please run IE as administrator for WIN 7, you need to install QuickTime plug-in if it is non-IE browser.
|
It displays “Resources are limited, failed to open video” after I log in the IPC.
|
Network bandwidth is not enough; change a switcher with bigger bandwidth.
|
Too many users logging in, and it is beyond the device code stream output capacity.
|
Disconnect the network or restart the device repeatedly, see 1.1 for more details.
|