Description
This article will cover the Building Config feature on Configtool.
We will be setting up multiple Floors using the VTO4202F-P-S
Prerequisites
- Initialized VDP devices Click here for Instructions
- Latest version of Configtool
Video Instructions
Step by Step Instructions
1. Make sure VTOs and VTHs are initialized and using the same password.
Note: VTOs and VTHs have different password requirements. VTOs will use 8-Character Alpha Numerical password and VTHs will use a 6-digit password
2. Navigate over to Building Config
3. Click on Global Parameters and you will get a popup to fill in login credentials.
4. Enter the information for the SIP server and login information to the units to give Configtool permission to login to the units and push the SIP Server Configuration. Then click on OK to save.
Global Parameter | |
---|---|
Center Number = Leave Default | Server Type = VTO |
Sever Address = Main VTO IP Address | Server Port = 5060 |
Sever Username = Enter VTO username | Sever Password = Enter VTO password |
Sip Domain = VDP | Register PWD = Leave Default |
VTO Username = Enter VTO username | VTO Password = Enter VTO password |
VTH Username = Enter VTH username | VTH Password = Enter VTH Password |