Thermal/DHI-ASI7213X-T1/Instructions/DSS Express/Email Notification For High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express

Revision as of 21:18, 16 October 2020 by Marques.Phillips (talk | contribs) (Description)

Email Notification For High Temperature Alert with DHI-ASI7213X-T1 and DSS Express

Description

This guide will show how to setup Email Notifications for High Temperature Alerts on DSS Express with the DHI-ASI7213X-T1

Note:

  • Email is setup using a 3rd party SMTP server configured to DSS Express
  • Emails are sent on High Temperature Alerts in this configuration

Prerequisites

Video Instructions

Step by Step Instructions

Add DHI-ASI7213X-T1 to DSS Express

1. From the Homepage of DSS Express

Click Device

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 8.jpg

2. Click Add

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 9.jpg

3. Enter the device details:

  • Device Name
  • IP Address
  • Username / Password

Click Add

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 10.jpg

4. The device will appear in the list

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 11.jpg

After a few moments the status will turn to Online

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 12.jpg

5. Click the pencil icon to edit the device settings

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 13.jpg

6. Click Video Channel

In the ChannelNumber field enter 1, then click inside the device settings, the Channel should appear in the list

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 14.jpg

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 15.jpg


Click the dropdown box under Features and enable the following:

  • IVS Alarm
  • IR Temperature Measurement
  • Face Recognition
  • Access Snapshot

Dahua Thermal Solution DHI ASI7213X T1 Add to DSS Express - 15-1.jpg

Setup Email On DSS Express

1. From the Homepage of DSS Express

Click Config

2. Select the server on the left side of the screen

Click Email

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 1.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 2.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 3.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 4.jpg

Add High Temperature Alarm To Kiosk In DSS Express

From the main menu select Config

1. Select the DHI-ASI7213X-T1 from the list in the left and expand until you find the Door, left click to select

Click Event Configuration

Face Recognition with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 8.jpg

2. Click the A & C Alarm section of the menu

Face Recognition with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 9.jpg

3. Click High Temperature Abnormal

Face Recognition with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 10.jpg

4. Click to toggle/enable the Alarm

Face Recognition with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 11.jpg

5. Click Email

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 5.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 6.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 7.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 8.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 9.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 10.jpg


Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 11.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 12.jpg

Email Notification with High Temperature Alert with DHI-ASI7213X-T1 and DSS-Express - 13.jpg