Notice: Firmware Links Under Maintenance We are currently undergoing maintenance on all firmware links. If any links are inaccessible, please email or contact Tech Support for the firmware. We appreciate your patience during the maintenance, thank you for your understanding.
Difference between revisions of "Perimeter Protection"
(→Suitable Sites) |
(→IVS Best Practices) |
||
Line 27: | Line 27: | ||
File:Perimeter_Protection_-_Best_Practices_3.jpg|Install cameras at a high position perpendicular to the road to monitor humans and vehicles. | File:Perimeter_Protection_-_Best_Practices_3.jpg|Install cameras at a high position perpendicular to the road to monitor humans and vehicles. | ||
File:Perimeter_Protection_-_Best_Practices_4.jpg|Install cameras at park or garage entrances to detect humans who goes into the motorway or vehicles which goes into a pedestrian area | File:Perimeter_Protection_-_Best_Practices_4.jpg|Install cameras at park or garage entrances to detect humans who goes into the motorway or vehicles which goes into a pedestrian area | ||
+ | File:Perimeter_Protection_-_Best_Practices_5.jpg|Configure tripwire rules at store entrances. | ||
</gallery> | </gallery> | ||
Revision as of 22:30, 1 July 2019
Contents
Perimeter Protection
Description
Perimeter protection provides enhanced IVS functionality to add the ability to use the Object Filter on several IVS features. The Object Filter can be set for Human or Motor Vehicle detection.
Supported on IVS Features: Tripwire, Intrusion, Fast Moving
Devices
Image | Models | Resolution | Specification | Manual | Main Firmware |
---|---|---|---|---|---|
DH-IPC-HFW5442E-ZHE | 4MP | 2019-03-01 | |||
IVS Best Practices
The installation site and installation type are essential to the final performance, this section introduces how to select a proper installation site and installation type
Suitable Sites
The sites need to provide a large visual field and be open and simple. There should be no frequently moving objects or drastic changes in lighting condition.
These kind of sites are suitable for cross detection at borderlines, communities, lawns, railways, and highways, access detection at underground garages, pedestrian streets, fall detection at lakes, and access detection at rooftops and private properties
Installation Requirements
Video Instructions
Instructions
1. Log into the WebUI of the device
2. Click Setting
3. Click Event>Smart Plan
4. Click the Light Bulb icon to select IVS
The icon will highlighted once selected.
Click Save
5. Click Event>IVS
6. The IVS menu will appear.
To create a new IVS rule click the + in the top right of the window
7. The new IVS rule will appear in the list.
Click the drop-down box to select the IVS rule type
Perimeter Protection is supported for the following IVS Features: Tripwire, Intrusion, Fast Moving
This guide will use Tripwire as an example, but the steps will be identical for the other Rule Types to add an Object Filter.
8. Click 'Draw Rule' to draw the detection
9. Click inside the video frame to begin drawing the TripWire. Right click once drawing is complete
10. Use the Parameter Setup on the right to configure the IVS rule settings
11. To create an Object Filter, check the box labeled 'Object filter'
Once checked there will 2 options for setting the Object Filter: Human or Motor Vehicle
12. Check the box next to which object type you with to detect using the IVS rule.
In this example the TripWire is set to only trigger when Human objects are detected AND triggering the IVS rule, in this case crossing the TripWire
13. Click Save to save all settings