Notice: Firmware Links Under Maintenance We are currently undergoing maintenance on all firmware links. If any links are inaccessible, please email or contact Tech Support for the firmware. We appreciate your patience during the maintenance, thank you for your understanding.
Difference between revisions of "Thermal/Temperature Monitoring/NVR Setup"
(→Thermal Configuration) |
|||
Line 165: | Line 165: | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_1.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_1.jpg|800px]] | ||
+ | |||
+ | 2. Click Parameters > Smart Plan | ||
+ | |||
+ | Use the dropdown to select the Thermal Channel | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_2.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_2.jpg|800px]] | ||
+ | |||
+ | 3. Click to enable the Thermal Temperature Monitoring Smart Plan | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_3.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_3.jpg|800px]] | ||
+ | |||
+ | Click OK | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_4.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_4.jpg|800px]] | ||
+ | |||
+ | Return to the Main Menu by closing the AI tab (clicking X) | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_4-1.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_4-1.jpg|800px]] | ||
+ | |||
+ | 4. Click Alarm | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_5.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_5.jpg|800px]] | ||
+ | |||
+ | 5. Click Thermal Alarm | ||
+ | |||
+ | Use the dropdown to select the Thermal Channel | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_6.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_6.jpg|800px]] | ||
+ | |||
+ | Select Thermal Temperature Monitoring | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_7.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_7.jpg|800px]] | ||
+ | |||
+ | 6. Check the box to enable feature | ||
+ | |||
+ | Check the box to enable desired camera hardware response on alarm: | ||
+ | |||
+ | * Camera Audio - audio from camera speaker | ||
+ | * White Light - light from camera | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_8.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_8.jpg|800px]] | ||
+ | |||
+ | To record Alarms, check the box next to Record Channel and select which channel(s) to record | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_9.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_9.jpg|800px]] | ||
+ | |||
+ | Click More Setting | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_10.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_10.jpg|800px]] | ||
+ | |||
+ | Check to enable Alarm Upload | ||
+ | |||
+ | Click OK | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_11.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_11.jpg|800px]] | ||
+ | |||
+ | ====Set temperature values for the alarm to trigger==== | ||
+ | |||
+ | 5. Click Setting next to Anatomy Temperature Alarm Rule to set the desired temperature values for the alarm to trigger | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_12.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_12.jpg|800px]] | ||
+ | |||
+ | Check the box to enable Temperature report - this will report/display all temperature values | ||
+ | |||
+ | Check the box to enable High Temperature Alarm - an alarm will be sent when the temperature is higher than or equal to this value | ||
+ | |||
+ | Click OK | ||
[[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_13.jpg|800px]] | [[File:Temperature_Monitoring_-_NVR_Setup_-_Thermal_Setup_13.jpg|800px]] |
Revision as of 23:24, 20 May 2020
Temperature Monitoring Solution Camera & NVR Setup
Contents
- 1 Temperature Monitoring Solution Camera & NVR Setup
This guide will cover the initial NVR, camera,and Blackbody setup and Configuration for the Thermal Temperature Monitoring Solution
If you're using a stand alone Thermal Camera (not plugged directly into NVR), follow the steps to set up Thermal Monitoring solution with stand alone Thermal camera
Description
This guide will cover the initial NVR, thermal camera, and Blackbody setup Configuration for the Thermal Temperature Monitoring Solution
Prerequisites
- DH-TPC-BF3221-T or DH-TPC-BF5421-T Thermal Hybrid Network Camera
- Thermal camera updated to latest firmware - How To Update TPC-BF5421-T Firmware
- JQ-D70Z Blackbody
- Temperature Monitoring Physical Setup
- Initial NVR Setup guide followed
Video Instructions
NVR Initial Setup and Firmware Upgrade:
Total Setup of Thermal Solution through NVR with Camera, including Record Setup and configuration at webUI:
Step by Step Instructions
NVR Initialization
Initialize the NVR over the network using a local computer
- Plug the Thermal camera into the PoE port on the back of the NVR
- Connect the NVR to a router/switch
- Connect computer to router/switch
1. Enter the IP address of the NVR (default http://192.168.1.108) in Internet Explorer
Proceed with Device Initialization
Select
- Region
- Language
- Video Standard
- Temperature Unit
Click Next
Scroll down to review the terms and check the box to agree
Click Next
Set the Time Zone and System Time
Create a password for the NVR and enter twice to Confirm
Click Next
Check the box to enable the Password Protection/Reset options for Email Address and Security Question
Click OK to proceed
A prompt will confirm a successful initialization
You can now log into the NVR's webUI to proceed with setup and configuration
Record Schedule Setup
Setup Video and Snapshot Recording for the Thermal Camera
From the Main Menu click Management > Camera
Under Registration
The thermal camera will appear in the Channel list as two channels, one for the visual channel and one for the thermal channel, in this example are Channels 1 and 2
Click Management > Storage
Click Schedule
Click Setting to adjust the Record schedule (when the camera will record) for the thermal camera channel
Use the interface to select the days and enter a Time Period. Select the Record type you wish to record for the camera: Alarm and IVS must be enable for the Temperature Alarm to record.
Click OK
The schedule will be updated
Click Copy
Select the other channel of the Thermal Camera (in this example Channel 2)
Click OK
Click the Snapshot tab
Configure the Snapshot schedule record settings the same way s the previous steps
Click OK to save
Click Storage > Record
Thermal Configuration
Configure the settings of the Thermal Camera to setup the Temperature Monitoring Solution
1. From the Main Menu of the webUI select AI
2. Click Parameters > Smart Plan
Use the dropdown to select the Thermal Channel
3. Click to enable the Thermal Temperature Monitoring Smart Plan
Click OK
Return to the Main Menu by closing the AI tab (clicking X)
4. Click Alarm
5. Click Thermal Alarm
Use the dropdown to select the Thermal Channel
Select Thermal Temperature Monitoring
6. Check the box to enable feature
Check the box to enable desired camera hardware response on alarm:
- Camera Audio - audio from camera speaker
- White Light - light from camera
To record Alarms, check the box next to Record Channel and select which channel(s) to record
Click More Setting
Check to enable Alarm Upload
Click OK
Set temperature values for the alarm to trigger
5. Click Setting next to Anatomy Temperature Alarm Rule to set the desired temperature values for the alarm to trigger
Check the box to enable Temperature report - this will report/display all temperature values
Check the box to enable High Temperature Alarm - an alarm will be sent when the temperature is higher than or equal to this value
Click OK
Thermal Camera Configuration: (click to expand each section)
Check latest firmware and upgrade
Open smart thermal of human body temperature measurement
Enable the Smart Thermal Smart Plan for the Thermal Camera
- Log into Camera
Click Setting
Click Smart Thermal > Smart Plan
Click the icon to enable the plan.
Click Save
Set rules of human temperature measurement
Set Rules Of Human Temperature Measurement
Configure the parameters for the Human Temperature Measurement
- Log into Camera
Click Setting
Click Smart Thermal > Thermal Temperature Monitoring
Check the box to enable human temperature measurement
Check the box to enable Temperature report - this will report/display all temperature values
Check the box to enable High Temperature Warning - an alarm will be sent when the temperature is higher than or equal to this value
Click Draw Rule to configure the rule box
Left click inside the frame to draw the box
Completed
Click Save
Set blackbody parameters
Set Blackbody Parameters
Configure the parameters for the Blackbody device for Human Temperature Measurement
- Log into Camera
Click Setting
Click Smart Thermal > Thermal Temperature
Select the Blackbody parameter tab
Check the box to enable
Click inside the video frame to select the green rule box
The rule needs to be drawn along the bold highlighted edge, just surrounding the highlighted area of the blackbody
Left click to drag and move the box and click the corners to resize the box
Click Save
Example of properly configured Blackbody box:
]Configure Advanced/Other Settings
Configure Advanced/Other Settings
Configure advanced/other parameters for the camera for Human Temperature Measurement
- Log into Camera
Click Setting
Click Smart Thermal > Thermal Temperature
Click the Smart Channel tab
Select which channel is used for Intelligent analysis
For normal scenes Visual channel is used to detect faces by default
For some scenes such as dark or with backlight environment, Thermal channel can be used
Snap Angle Filter - larger the value, easier it is to capture the side face
For example , when value is 1 , only the front face can be detected
Click SaveCheck environment temperature
Check Environment Temperature
If the default temperature parameters are not accurate this situation will affect the human body temperature measurement.
If human body temperature is inaccurate, try the following steps:
Step 1 - Ambient temperature
- Log into Camera
- Setting > Smart Thermal > Human temperature measurement > Others
- Use thermometer to detect the real ambient temperature on site and enter the number
- Click Save
Step 2 - Human temperature correction
- Use a thermometer to detect the real Human body temperature:
Calculate the difference between real Human body temperature and measure the temperature from the thermal camera, enter this value in Human Temperature correction field.
Smart Thermal > Human Temperature Monitoring > Blackbody parameter:
For example: real Human body temperature is 98.6F (37C), measure temperature in thermal camera is 100F (37.8C)
Human Temperature correction should be 98.6 - 100 = -1.4
Click SaveEvent Verification
Event Verification
Once configuration is complete, go to Live interface to verify temperature measurement
- Log into Camera
- Check measurement value on screen
- Compare it with the value on the frontal temperature gun, thermometer ( if available)