Thermal/Temperature Monitoring/3rd Party VMS/Milestone/Full Installation

Revision as of 18:30, 5 November 2020 by JP (talk | contribs) (Step by Step Instructions)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Dahua Temperature Monitoring with Milestone Full Installation

Description

This guide will cover the full installation of Thermal Temperature Monitoring Solution with Milestone - XProtect Smart Client 2020 R1

Prerequisites

Video Instructions

Step by Step Instructions

Milestone logo.jpgInstall Plugin

Install Dahua Plugin

Description

This guide will show how to install the Dahua Thermal Plugin for Milestone

Prerequisites

Click to download the Dahua Thermal Plugin

Video Instructions

Step by Step Instructions

1. Double click Dahua Thermal Plugin.msi - Dahua Thermal Plugin to run the installer

Temperature Monitoring - Milestone - Install Plugin - 1.jpg

2. Click Next

Temperature Monitoring - Milestone - Install Plugin - 2.jpg

3. Select the installation path.

This should be chosen under the "MIPPlugins" folder which is inside the directory of the Milestone installation folder.

Temperature Monitoring - Milestone - Install Plugin - 3.jpg

4. Proceed through the installer by clicking Next

Click Close once the installation is complete

Error creating thumbnail: File missing

Milestone logo.jpgConfigure Thermal Camera For Use With Milestone

Setup and Configure Camera

Description

This guide will show how to initialize and configure the Dahua Thermal camera in preparation for use with Milestone

Prerequisites

  • Dahua Thermal camera powered on and connected to network

Step by Step Instructions

Initialize Camera

Please reference this guide for initial setup of the Thermal camera:

Stand Alone Thermal Camera Initial Setup

Configure Camera

1. Log into the Web interface of the camera

Click Setting


2. Click Smart Thermal > Smart Plan

Click to enable the Thermal Temperature Monitoring and click Save

Thermal Temperature Monitoring - Milestone - Camera Configuration - 1.jpg

3. Click Thermal Temperature > Thermal Temperature Monitoring

  • Check the box to enable
  • Check the box to enable High Temperature Warning

Note: If you select 'Temperature report' , we will get all alarm notifications when camera detects any body temperature, no matter if it's higher or lower

  • Check Snapshot
  • Click Save

Thermal Temperature Monitoring - Milestone - Camera Configuration - 2.jpg

4. Click Smart Thermal > Smart Channel

Click to enable Crop Images

Click Save

Thermal Temperature Monitoring - Milestone - Camera Configuration - 3.jpg

Milestone logo.jpgAdd Thermal Camera and Configure Milestone Temperature Detection Alarm Event

Add Camera To Milestone and Configure Alarm Event

Description

This guide will show how to add the camera to the Milestone server and configure the alarm event for Temperature Monitoring

Prerequisites

  • Milestone Corporate 2019 R3, device pack 10.8a

Step by Step Instructions

Add device in Milestone XProtect Management Client

1. Add Device to Recording Server by left clicking Recording Servers

Right click the server

Select Add Hardware

Temperature Monitoring - Milestone - Configure Milestone - 1.jpg

2. Select Manual Add

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 2.jpg

3. Click Add

Enter the username and password for the camera

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 3.jpg

4. Select ONVIF for device driver

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 4.jpg

5. Enter the IP address of the camera

Select (Auto-detect)

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 5.jpg

The software will automatically detect the camera

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 6.jpg

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 6-1.jpg

6. Check the box to enable all Hardware for the camera

Temperature Monitoring - Milestone - Configure Milestone - 7.jpg

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 7-1.jpg

Click Finish

Temperature Monitoring - Milestone - Configure Milestone - 8.jpg

The camera will appear in the list

Temperature Monitoring - Milestone - Configure Milestone - 9.jpg

Add event in Milestone XProtect Management Client

1. Select Cameras

Then left click to select the Thermal camera in the list

Click the Events tab

Temperature Monitoring - Milestone - Configure Milestone - 10.jpg

2. Click Add to create a new Event

Temperature Monitoring - Milestone - Configure Milestone - 11.jpg

3. Find and select Temperature Detection Started in the list

Click OK

Temperature Monitoring - Milestone - Configure Milestone - 12.jpg

4. Repeat the process again to create a new Event

  • Click Add
  • Select Temperature Detection Stopped
  • Click OK

Temperature Monitoring - Milestone - Configure Milestone - 13.jpg

5. Left click to select the 2nd channel of the Thermal camera

Repeat the previous steps on the 2nd channel to configure both events

Temperature Monitoring - Milestone - Configure Milestone - 14.jpg

Temperature Detection Started / Temperature Detection Stopped Event configured on 2nd channel:

Temperature Monitoring - Milestone - Configure Milestone - 15.jpg

Add rules for event

1. Select Rules

Right click Rules

Select Add Rule

Temperature Monitoring - Milestone - Configure Milestone - 16.jpg

2. Enter a name for the Rule

Click event

Temperature Monitoring - Milestone - Configure Milestone - 17.jpg

3. Select Devices > Configurable Events

Temperature Monitoring - Milestone - Configure Milestone - 18.jpg

Find Temperature Detection Started in the list and click to select

Click OK

Temperature Monitoring - Milestone - Configure Milestone - 19.jpg

4. Click devices/recording/server/managementserver

Temperature Monitoring - Milestone - Configure Milestone - 20.jpg

5. Left click to select the Thermal camera in the list

Click Add

Temperature Monitoring - Milestone - Configure Milestone - 20-1.jpg

6. Repeat the process for the 2nd channel

Click OK

Temperature Monitoring - Milestone - Configure Milestone - 21.jpg

7. Click Next

Temperature Monitoring - Milestone - Configure Milestone - 22.jpg

8. Configure the schedule for the event

In this example we select All days by clicking Day of week is then selecting all Days

Temperature Monitoring - Milestone - Configure Milestone - 23.jpg

9. Click Next

Temperature Monitoring - Milestone - Configure Milestone - 24.jpg

10. Select action to perform when the event is triggered

In this example we select

  • Record - Start recording on <devices>

Temperature Monitoring - Milestone - Configure Milestone - 25.jpg

  • Log - Make new <log entry>

Click logentry

Temperature Monitoring - Milestone - Configure Milestone - 26.jpg

11. Click to add each type of System Information to the log template

Click OK

Temperature Monitoring - Milestone - Configure Milestone - 27.jpg

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 28.jpg

12. Select Perform stop action on <event>

Click Next

Temperature Monitoring - Milestone - Configure Milestone - 29.jpg

13. Click Finish

Temperature Monitoring - Milestone - Configure Milestone - 30.jpg

Alarm configuration

1. Select Alarm Definitions

Right click Alarm Definitions

Select Add New

Temperature Monitoring - Milestone - Configure Milestone - 31.jpg

2. Check to Enable

Enter a name - Temperature Detection Start

Temperature Monitoring - Milestone - Configure Milestone - 32.jpg

3. Use the dropdown box next to Triggering event to select Device Events

Temperature Monitoring - Milestone - Configure Milestone - 33.jpg

Use the dropdown box to select TemperatureStart

Temperature Monitoring - Milestone - Configure Milestone - 34.jpg

4. Click Select to select which devices for use with the alarm

Temperature Monitoring - Milestone - Configure Milestone - 35.jpg

5. Select the Thermal camera in the list, click Add

Temperature Monitoring - Milestone - Configure Milestone - 36.jpg

6. Repeat the process for the 2nd channel of the camera

Click OK

Temperature Monitoring - Milestone - Configure Milestone - 37.jpg

7. Click Save

Temperature Monitoring - Milestone - Configure Milestone - 38.jpg

8. Another rule must be created for the event end

Right click Alarm Definitions

Select Add New

Temperature Monitoring - Milestone - Configure Milestone - 39.jpg

9. Click to Enable

  • Enter a name - Temperature Detection Stopped
  • Use the dropdown box next to Triggering event to select Device Events
  • Use the dropdown box to select TemperatureEnd
  • Click Select to select which devices for use with the alarm
    • Select the Thermal camera in the list, click Add
    • Repeat the process for the 2nd channel of the camera

Temperature Monitoring - Milestone - Configure Milestone - 40.jpg

Both Alarms created

Temperature Detection Started Temperature Detection Stopped

Temperature Monitoring - Milestone - Configure Milestone - 41.jpg