Notice: Firmware Links Under Maintenance We are currently undergoing maintenance on all firmware links. If any links are inaccessible, please email or contact Tech Support for the firmware. We appreciate your patience during the maintenance, thank you for your understanding.
Difference between revisions of "Record"
(→Glossary) |
(→Glossary) |
||
Line 11: | Line 11: | ||
==Glossary== | ==Glossary== | ||
− | * Anti-dither - Period of time the alarm signal lasts (in seconds). This time does not include latch time. During the alarm process, the alarm signal can begin anti-dither time if the system detects the local alarm again. The screen prompt, alarm upload, | + | * Anti-dither - Period of time the alarm signal lasts (in seconds). This time does not include latch time. During the alarm process, the alarm signal can begin anti-dither time if the system detects the local alarm again. The screen prompt, alarm upload, email and etc. will not be activated. For example, if you set the anti-dither time as 10 seconds, each activation will last 10 seconds. During the process, if the system detects another local alarm signal at the 5th second, the buzzer,tour, PTZ activation, snapshot, and record channel will begin another 10s while the screen prompt, alarm upload, and email will not be activated again. After 10s if the system detects another alarm signal, it can generate an alarm since the anti-dither time is out |
* Latch - Delay (in seconds) before the system begins detecting for the same alarm/event | * Latch - Delay (in seconds) before the system begins detecting for the same alarm/event | ||
* Show Message | * Show Message |
Revision as of 18:55, 5 February 2020
Contents
Recording
Record Schedule
- Green stands for General record.
- Yellow stands for MD record.
- Red stands for alarm record.
- Blue stands form intelligent record.
- Orange stands for MD&Alarm record.
- Purple stands for POS record.
Glossary
- Anti-dither - Period of time the alarm signal lasts (in seconds). This time does not include latch time. During the alarm process, the alarm signal can begin anti-dither time if the system detects the local alarm again. The screen prompt, alarm upload, email and etc. will not be activated. For example, if you set the anti-dither time as 10 seconds, each activation will last 10 seconds. During the process, if the system detects another local alarm signal at the 5th second, the buzzer,tour, PTZ activation, snapshot, and record channel will begin another 10s while the screen prompt, alarm upload, and email will not be activated again. After 10s if the system detects another alarm signal, it can generate an alarm since the anti-dither time is out
- Latch - Delay (in seconds) before the system begins detecting for the same alarm/event
- Show Message
- Alarm Upload
- Post-Record
- Tour
- Picture Storage
- Buzzer
Basic Recording