Difference between revisions of "Access Control"
(→FAQ) |
(→FAQ) |
||
Line 329: | Line 329: | ||
==FAQ== | ==FAQ== | ||
− | Q: Why don't entries display "User ID" and "Username" when unlocking with PIN codes? | + | Q: Why don't entries display "User ID" and "Username" when unlocking with PIN codes in DHI-ASC3202B? |
[[File:PIN_Code_Authentication_Enabled.png|400px]] | [[File:PIN_Code_Authentication_Enabled.png|400px]] |
Revision as of 23:58, 2 November 2023
Access Control Generations
Default Information | |
---|---|
IP | 192.168.1.108 |
Username | admin |
Password | admin123 |
Enter PINs | USERID#6-digit code# -> i.e: 1#123456# |
Card + PINs | Card Swipe + 6-digit code# -> i.e: 123456# |
Note: DHI-ASC2204C-S will require to be initialized on firmware 8-23-2021 and above. Any firmware build date below this will use the default information
Instructions
Software Downloads
Application | Description | Specifications | Manual |
---|---|---|---|
Configtool Locate and manage dahua devices on network |
|||
SmartPSS AC This software is designed to manage Dahua Access Controller |
|||
DSS Express V8 (NEW) Pay-as-you-go Security Software for SMB |
|||
DSS Pro V8 (NEW) High Available Security Software for Enterprise |
|||
DSS Express V7 Easy-to-Use and Reliable Dahua VMS |
|||
DSS Pro V7 Comprehensive and Expandable Dahua VMS |
Default Information | |
---|---|
IP | 192.168.0.2 |
Username | admin |
Password | 123456 |
Software Downloads
ACS Config Tool
Click Here To Download ASC Config ToolSmartPSS V2.003 with Access Control
Click Here To SmartPSS with Access ControlInstructions
- How to Update ASC1204B Firmware
- How to Connect Electronic Buzzer
- How to Setup DHI-ASI1201A-D
- How to Setup DHI-ASR1101A
- How to Setup DHI-ASI1212A
- How to Factory default access controller unit
- How to Setup DHI-ASC1204B
- How to wire exit button to DHI-ASC1204B
- How to setup/ sync date and time of DHI-ASC1204
- Door Controller - Basic User and Access Rights Setup
- How To Import & Export Access User List
- How to Change IP address of ASC1204B/C
Not Working
- Pin codes can't be setup for all users SmartPSS or DSS Express
- Logs won't show which user unlock the door.
- Gen 1 controller does not support Holiday Function on all software platform.
Information | |
---|---|
Default IP | 192.168.1.108 |
Enter PINs | USERID#6-digit code# -> i.e: 1#123456# |
Card + PINs | Card Swipe + 6-digit code# -> i.e: 123456# |
Function | Web GUI (Main Control) |
SmartPSS Lite | DSS Pro 8.2 |
---|---|---|---|
First Card Unlock | No | Yes | Yes |
Interlock | No | No | No |
Anti-pass | No | Yes | Yes |
Multi-card Unlock | No | Yes | Yes |
Holiday Door Schedule | Yes | Yes | Yes |
Heat Alarm | Yes | No | No |
HID26 card number | Yes | No | No |
HID Facility Site Code | Yes | No | No |
Import card number in bulk | Yes | No | Yes |
Export card number in bulk | Yes | No | Yes |
Instructions
Products
Models | Image | Type | Description | Specification | Manual | Firmware | |
---|---|---|---|---|---|---|---|
Video Access Controller | |||||||
DHI-ASI8213SA-W | Video Access Controller | Build Date: 09-11-2023
| |||||
Web Controller | |||||||
DHI-ASC3202B | Web Controller | Build Date: 03-06-2024
| |||||
Elevator Control Solution | |||||||
DHI-ASC2204C-H | Elevator Master Access Controller |
|
Coming Soon | ||||
DHI-VTM416 | Elevator Control Module |
|
Coming Soon | ||||
GEN 2 | |||||||
DHI-ASC2204C-S | Access Controller |
|
Build Date: 11-08-2022
| ||||
GEN 1 | |||||||
DHI-ASC1204B | Four Door Access Controller |
|
Build Date: 12-31-2019
| ||||
DHI-ASC1204C | Four Door Access Controller |
|
Build Date: 12-31-2019
|
Models | Image | Type | Description | Frequency | Interface | Specification | Manual | Firmware |
---|---|---|---|---|---|---|---|---|
ASR2100Z-B | RFID/Bluetooth Reader |
|
|
|
Coming Soon | |||
DHI-ASR1100B-V1 | RFID Reader |
|
13.56MHz(Mifare) | RS-485 protocol | Build Date: 06-19-2023
| |||
DHI-ASR1101M-V1 | RFID Reader |
|
13.56MHz(Mifare) | RS-485 protocol | Build Date: 01-04-2022
| |||
DHI-ASR1102A(V3) | Fingerprint reader |
|
13.56MHz(Mifare) | RS-485 protocol | ||||
DHI-ASR2200A | Water-proof Reader |
|
13.56MHz(Mifare) |
|
Coming Soon | |||
DHI-ASR2101A | Water-proof RFID Reader |
|
13.56MHz(Mifare) |
|
Coming Soon | |||
DHI-ASI2212H-W | Waterproof Access Reader and Controller |
|
13.56MHz(Mifare) |
|
Build Date: 11-04-2022
| |||
DHI-ASR1200D | Slim Water-proof RFID Reader |
|
13.56MHz(Mifare) |
|
Build Date: 07-23-2021
| |||
DHI-ASA2212A | Standalone Time Attendance |
|
13.56MHz(Mifare) | N/A | Build Date: 07-19-2018
| |||
DHI-ASI1212D | Water-proof Fingerprint Standalone |
|
13.56MHz(Mifare) |
|
Build Date: 08-11-2021
| |||
DHI-ASR1201D | Slim Water-proof RFID Reader |
|
13.56MHz(Mifare) |
|
Build Date: 07-23-2021
| |||
DHI-ASR1100B | RFID Reader(Wiegand) |
|
13.56MHz(Mifare) |
|
Build Date: 07-23-2021
| |||
DHI-ASR1101A | RFID Reader |
|
13.56MHz(Mifare) |
|
Build Date: 12-24-2020
| |||
DHI-ASR1102A(V2) | Fingerprint reader |
|
13.56MHz(Mifare) | RS-485 protocol | Build Date: 08-20-2021
| |||
DHI-ASR1101M | RFID Reader All metal buttons |
|
13.56MHz(Mifare) |
|
Build Date: 09-17-2021
|
Model | Image | Type | Description | Specification |
---|---|---|---|---|
DHI-ASM100 | Card Enrollment Reader |
|
||
DHI-ASM202 | Fingerprint Enrollment Reader |
|
||
Philips IC MF11CS50 | IC Card |
|
||
IC-SM | IC Key Fob |
| ||
DH-PFM321D-US | Power Supply |
|
||
DH-PFM320D-US | Power Supply |
|
||
ASM102(V2) | Fingerprint Enrollment Reader |
|
FAQ
Q: Why don't entries display "User ID" and "Username" when unlocking with PIN codes in DHI-ASC3202B?
A: When "PIN Code Authentication" is enabled, it takes precedence over the information displayed in the logs. As a result, the username and user ID are no longer shown, as users no longer need to include the user ID when entering their password.